Mobile Gateway Configuration (Configuration Center)
Configuration Center is a Windows® based software and the primary tool for configuring Galooli’s K2 and MILA7 smart fleet gateways.
It uses standard Windows features and styles, such as toolbars, menus, and property pages.
The configuration center uses a network protocol to communicate with the gateway via a serial connection.
To install the configuration center, use the following link
Using the Configuration Center you can:
Read the current metrics and settings of the gateway
Download/upload files with existing settings
Upgrade/downgrade gateway’s firmware and MILA 7 firmware
Calibrate the accelerometer
Pair between MILA7 to ELM327
Log-In Process
It is very easy and intuitive for the user to log in to the Configuration Center platform. Username (Email) and password are the same as those configured on the main Galooli solution platform - Galooli Solution | Log In Process
Upon successful registration, you will no longer be required to enter a username or password, unless you have deleted the Configuration Center and reinstalled it or you have performed a version update.
If you are a global user, please enter the name of the organization after the email using &.
Users who forget their password should reset the password via the Galooli Solution platform - How to Reset Password?.
If you are unable to register despite recovering your password, you must verify that you have the appropriate permissions to access Configuration Center. The permissions called “Hardware Configuration Tools”. Permission Management | General Authorization Permission
In the event you use a Windows operating system on your computer, you may receive a security warning when you attempt to install Configuration Center or when you perform a version update of Configuration Center. To proceed with the process, please refer to the image below.
Minimal System Requirements
System Requirements |
|
Processor: Multicore Intel/ AMD Processor | Windows 10 and higher |
Memory: RAM -2GB or Higher | .NET Framework Version 4.7 and up |
Note! 64-bit system is recommended, but the 32-bit system is fully supported as well. |
File Menu
The file menu contains commands to open and save configuration files. Configuration files may also be read from or written to a target PAR File including menu commands, set defaults, and restore settings.
Load – loads gateway parameters from a file
Save as – Saves parameters to a file
Load Defaults – Loads Configuration Center Default parameters
Set Defaults – Save Configuration Center Default Parameters
Restore Factory Defaults – Restores the factory default parameters of the gateway
Administrator Login – Used only by Galooli
Status
The Status tab allows the user to see and track changes of the gateways that are connected to the Configuration Center.
Unit:
Unit ID - The gateway ID
Time Stamp - Time and date received through the SIM cardVersion - A hardware version that cannot be modified and a software version that can be updated
Signal Level - Percentage of signal strength of the modem received through the SIM card
Status - Status of modem received through the SIM card
Reporting Reason - Description of the action that makes the modem reportExternal Voltage - The voltage that the gateway receives
Backup Voltage - The voltage that the internal battery of the K2 receives
Vibration Detected - Movement indicator of the gateway (ACTIVE / NOT ACTIVE)GPS:
Time Stamp - Time and date received through the GPS
Location - GPS coordinates
Satellites - Amount of received satellites connections
Hdop - The accuracy level of the position, should be between 0.6 to 1.1
Fix - GPS location information quality. should be “Fix 3D”
Heading - The direction that the gateway is facing (North/South)
Speed - Speed that the unit picks up with the help of GPS
Altitude - The height the unit picks up
Distance - The accumulating distance the unit has traveledInputs / Outputs:
Input 1-5 - Indication of sensor activityFuel:
Source - Active source of fuel
Level - The raw value that is obtained from the sensorDriver Identification:
Time Stamp - A time when the driver identified himself with one of the identity gateways
Matching Type - Indication of whether or not the code selected by the driver matches the information that was configured
Driver Code - The code of the specific gateway
Trip Type - Definition of a private or business trip (keypad only)Driver Behavior:
Harsh Acc - Harsh acceleration alert
Harsh Turn - Harsh turn alert
Harsh Brake - Harsh brake alert
Crash - Crash alert
Severe Acc - Severe acceleration alert
Severe Turn - Severe turn alert
Severe Brake - Severe brake alertConnected - Indication of the presence of ADAS (Advanced driver-assistance systems)
LDW Left - Crossing a lane to the left
Headway - Distance in seconds from the vehicle in front
CAR - Indication about a vehicle
Error - An internal error of the ADAS
LDW Right - Crossing a lane to the right
TSR - Identification of the speed limit on the road according to signs
PED - Indication about a pedestrianIgnore Errors - Not in use
Advance Diagnostics
Diagnostic Status - Units connection indication
Engine Speed
Oil Temperature
Oil Pressure
Pedal Position
Engine Coolant Temp.
Engine Load
Air Temperature
Distance Availability
Fuel Availability
Check Engine
*All the rows explained above can be minimized by clicking on the name of the row
Configuration
The Configuration tab allows the user to make changes and adjustments to gateways
Communication
The purpose of Communication is to configure the K2 communication settings with the Galooli server.
Server URL – Type in the GALOOLI server URL
Network APN – Type in the access point name of the mobile network (GPRS Enabled)
Network User – Type in if the parameter is required by the mobile network
Network Password – Type in if the parameter is required by the mobile network
Report Intervals
The purpose of Report Intervals is to configure the K2 reporting intervals to the Galooli Server.
Ignition On Interval - Type in the time interval in seconds in which the K2 gateway will send a report to Galooli Server while the engine is on. (default & recommended setting is 60 seconds)
Ignition Off Interval - Type in the time interval in seconds in which the K2 gateway will send a report to Galooli Server while the engine is off. (default & recommended setting is 900 seconds)
Inputs
The purpose of Inputs is the general configuration of the K2 inputs.
Every input includes 2 tabs:
Status Thresholds - allows you to manage the voltage although, it is recommended by Galooli to not change the default.
Activation Delay - allows you to delay the time between the electrical voltage and the bulb that alerts about it.
Input 2 - It is possible to choose between 2 types of inputs. Normal Mode and Temperature Sensor
Input 3 and 4 - It is possible to choose between 3 types of inputs. Normal Mode/Pulse Counter/Temperature Sensor(3-Wires)
Driver Identification & Immobilizer
The purpose of Driver Identification & Immobilizer is to configure the method of driver identification such as Dallas button, keypad, etc.
Identification Device – Select the external identification device (Dallas Button, Keypad panel, Dallas and Keypad, RFID Device)
Operating Mode:
Disabled - When the immobilizer option is disabled, the gateway can be immobilized only via ZON MAX or Configuration Center.
Mobilized by any code - The gateway will be mobilized by any driver identification code. (The access code will still be relevant for driver identification in ZON MAX).
Mobilized by Authorized code only – The gateway will be mobilized only by the codes listed in the Authorize Drivers section.Mark checkbox to immobilize the gateway when jamming is detected. That means that the ignition switch will be disabled if the gateway (K2) will detect a jamming device. The gateway will not turn off an already running engine.
Authorize Drivers
The Authorize Drivers is a direct continuation of the previous section (Driver Identification & Immobilizer).
This section allows you to select the type of ID code and digits of the ID code only if the user chooses “Mobilize by Authorized code only” in the Immobilizer Control section.
Matching Mode:
Disabled - The mobilizer code would not be in use.
Unique ID - This option allows to enter a specific code of the identification device that burned into the unit in the factory so that only the driver holding this specific gateway number can drive the vehicle.
User Group ID - This option allows independently setting the same identification code for multiplay drivers. The group id essentially overwrites the gateways code and exchanges it to a set-id that identifies the group rather than an individual user. The identification is done via the first 4 digits of the code entered into the system.
User ID - This option allows to set a unique identification code for a specific user that is different from the code that burned into the unit in the factory.
Fuel
The purpose of Fuel is to Configure the fuel control settings
Source:
None – Select when there’s no fuel input.
Sender – Select when the fuel input is a sender.
Sender Type B - Select only if instructed by Galooli Support department.
Capacitive Sensor- Select when the fuel input is a designated capacitive sensor (LLS).
Engine Computer– Select when the fuel input comes through the engine diagnostic.
Digital Pressure Sensor – Select when the fuel input is a digital pressure sensor.
Noise Factor:
The noise factor selections are from “Low” to “Extreme”. The recommendation is to use the “Standard” option.
Driver Behavior
The purpose of Driver Behavior is to configure the driver behavior settings.
Speed Alert – Set an alert when exceeding a certain speed (presented in Km)
Vehicle Type – Select the vehicle type from the selection menu. This will automatically update the thresholds for acceleration, brake, and turn events. These thresholds will then be the basis for event notifications and user alerts if the driver exceeds the threshold
Users can also set the thresholds manually by selecting Manual Settings. This will open a list of all thresholds where the user can add the G parameters.
Buzzer Control
The purpose of Buzzer Control is to configure the buzzer settings.
In general, the buzzer serves to alert the driver whenever a certain event occurs, as described below.
Advanced Diagnostics
The purpose of Advanced Diagnostics is to configure the advanced diagnostic settings.
System Status Source - Select which source will indicate if the gateway is ON/OFF.
Distance Source - Select the distance source for the gateway GPS/Odometer:
Internal GPS -
Engine Computer -
Engine Computer - Select which source connects to the engine computer.
ADAS - Select one of the following:
CAN on MILA7 >> Mobileye (After Market) or Mobileye (OEM) Locked version of Mobileye or MOVON
CAN on K2 >> Mobileye (After Market) or Mobileye (OEM) Locked version of Mobileye or MOVON
Power Management
The purpose of Power Management is to save energy when the gateway is not active.
Time to Power Down - Set a time for the gateway to enter sleep mode. In Sleep mode, the gateway's communications are off
Wake up interval - Set time intervals in which the gateway will wake up and connect to Galooli servers
MAX wake up time - Set a max time for connection attempts (bad reception)
Time to use backup only - Set a time duration for consuming power only from the backup battery
Minimum backup Voltage - Set a minimum voltage in which charging will re-start
Charge only while On - Cancels the charging of the internal battery of the gateway by the vehicle's battery
*All the rows explained above can be minimized by clicking on the name of the row
File Menu
The file menu contains commands to open and save configuration files. Configuration files may also be read from or written to a target PAR File including menu commands, set defaults, and restore settings.
Load – loads gateway parameters from a file
Save as – Saves parameters to a file
Load Defaults – Loads Configuration Center Default parameters
Set Defaults – Save Configuration Center Default Parameters
Restore Factory Defaults – Restores the factory default parameters of the gateway
Administrator Login – Used only by Galooli
Commands Menu
The commands menu allows you to read all current values from the gateway, as well as to write new values. The menu contains the following commands:
Status Requests – Query the current gateway’s status
Read All Parameters – Reads settings from the gateway to Configuration Center
Write All Parameters – Writes settings from Configuration Center to the gateway
Output Off – Disables immobilizer Output (immobilize)
Output on – Enables immobilizer Output (mobilize)
On-Board Accelerometer Calibration – This button will start automatic calibration, please make sure the vehicle is leveled.
MILA7 ELM327 Pairing Request - This button will start the Bluetooth pairing process between MILA7 and the ELM237.
Administration Menu
The administration menu allows you to send system & user commands and change firmware versions. The menu contains the following commands:
Text Message – Send SMS from the gateway
Reset Unit – This gateway will start an automatic reset of the gateway
Clear Internal Log – This button will send a command to the gateway to clear its log
Clear Counters – Clears Distance and Pulse Counters
Factory Reset – Returns the internal parameters to the factory default state
AT Terminal – For Galooli use only
Force Unit Time – Force the internal clock if the gateway, can’t integrate with the GPS
Storage Mode – Disabling the gateway internal battery when not in use (Serial connection only)
Triton K2 –This button will open the upgrade/downgrade screen (Serial connection only)
MILA7 – This button will open the upgrade/downgrade screen (Serial connection only)
GPS Patch – For Galooli use only. This patch is intended to update the GPS version of very old GPS receivers. As a result of the patch, GPS receivers that had stopped receiving locations are now receiving them again.
Service Center Menu
OTA Center (Over The Air Center) - To update a version of hardware via OTA connection please use the My Versions solution.
Scope - Galooli use only
View Menu
Restore - This button resets the structure of the screen in case changes were made
Status Overview
The status overview presents accessible live information about the gateways, only when the gateways are connected to the Configuration Center via SIM card (OTA - over the air) or via serial communication (USB connected to the computer with a serial adapter)
Color indication:
Green color -The information displayed is in the correct range
Red color - The information displayed is not in the correct rangeInformative indication:
Unit ID which appears on the gateway
The last stamp time status of the gateway as presented in section 3
The status of the ignition switch indicator in the car (digital input 1)
The external voltage that the gateway receives from the electricity source
The voltage of the backup internal battery
Indication of the connection to the GPS
Indication of the connection to the Server (OTA or serial communication)
Explorer
Links that lead to tabs on the right (the Status and Configuration tabs)
Double click on the tabs o the left side will open the suitable tab on the right side
The Tools tab
Messages - After pressing this button, a page appears on the right side of the screen that shows the internal connection of the gateway with the Configuration Center
Simulator- Galooli use only