Web Local Host Connection
The Cut Through via Modbus TCP allows you to get data and even set it depending on the data types.
The example below illustrates how to use Modbus TCP communication for an inverter, but you may use this method for all devices connected via Modbus TCP.
Please note that before starting the process, you must verify whether the parameters you are interested in can be set.
Cut Through Progress
Open the Power Center >> Connect to the Elara gateway via serial/OTA connection >> Click on “Read Configuration” >> Click on “Status” >> Click on “Configuration” tab. Now you can see all the information about the inverter.
The next step is to locate and copy the “Destination IP” in order to be able to make the "Cut Through":
Inverter IP - Select the "Configuration" tab >> Open the "Group: Inverter” >> Double click on the “eth” >> Copy the “Device IP.
2. Click on “Direct-Comm” >> Choose “Ethernet (WEB: LOCALHOST: 90)” >> Fill in the information you obtained in the previous step >> Keep the “Direct-Comm” window open.
"Destination IP" = Inverter IP
3. In your web browser, enter "localhost:90" in the URL field.
4. After few moment the device control screen will be displayed directly to you.
If for some reason the device control screen does not appear even though all the steps has been done correctly, please change the “Cut Through” method to - Modbus TCP Cut Through Manual Connection
5. Log in with the credentials of the specific device.
6. Please refer to next documents for more information about how to get and set data via the internal device control platforms: