The latest version of the Galooli solution incorporates features that reflect our open dialogue with our customers and Galooli's desire to facilitate and improve the system's use. The purpose of this article is to provide information about the main features of this version.
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panorama Application
AI-Based Analysis New Group Of Dashboards
We have made significant improvements to the AI-Based Analysis dashboard list. Currently, there are two main dashboards and each dashboard includes sub-dashboards.
This new set of dashboards is now available to Gold license plan type customers too.
The navigation between dashboards and views are seamless.
Among the dashboards included in the group are:
Galooli Analyst Dashboard - A new dashboard introduced in the previous version. This dashboard containing many items and cards, there for divided into multiple "sub-dashboards":
Overview
Solar Insights
Fuel Insights
Generator Insights
Battery Insights
Galooli Planners Dashboards
Refuel Planner Dashboard
Maintenance Visits Planner Dashboard
Read More - AI-Based Analysis Listand improve the system's use. The purpose of this article is to provide information about the main features of this version.
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panorama Application
AI-Based Analysis New Group Of Dashboards
We have made significant improvements to the AI-Based Analysis dashboard list. Currently, there are two main dashboards and each dashboard includes sub-dashboards.
This new set of dashboards is now available to Gold license plan type customers too.
The navigation between dashboards and views are seamless.
Among the dashboards included in the group are:
Galooli Analyst Dashboards Collection - Allows you a better understanding of your data with AI-powered analysis delivered in a simple, straightforward manner.
Overview
Solar Insights
Fuel Insights
Generator Insights
Battery Insights
Galooli Planners Dashboards Collection - forecast refueling and maintenance needs for improved site visit planning and higher uptime, using our AI tools that learn the usage patterns.
Refuel Planner Dashboard
Maintenance Visits Planner Dashboard
Read More - AI-Based Analysis List
CEO Dashboard
Panorama Analytics Mode has been enhanced with a new CEO dashboard. The dashboard can be used to make data-driven decisions based on operational expenses and tenant consumption revenue.
Read More - https://galooli.atlassian.net/wiki/x/AQAt1Q
Video Streamer
The Panorama Unit Live View now includes the option of viewing a live video stream of your site.
Read More - Video Streamer
Colocation/Tenant Card Display
Changes have been made to the Colocation/Tenant card regarding the presentation of tenant power types. The card will display differently based on the type of tenants on the site; for example, a site with only AC or DC tenants will appear different from one with both AC and DC tenants.
Separating the display of tenants to AC and DC tenant due to different billing methods and SLA agreements.
Read More - https://galooli.atlassian.net/wiki/x/J4BPr
Live Mode Rectifier Card
The rectifier expanded views view now include a “Control” menu with the action “Reset Rectifier”. Currently, the menu will only be available for the Vertiv M830B NCU rectifier.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2891743233/Site+Rectifier+Card#Expanded-View
Alarms Naming Convention
As of this version, all alarms originating from site hardware (rectifiers, generators, etc.) will include the phrase "Alarm Internal XXX", while alarms originating from Galooli's logic will called "Alarm Galooli XXX".
All Golooli applications, including Panorama and Pro, will be affected by the change.
Observation Type Alarms Changes
A change has been made to the observation type of alarms.
All of the observation type alarms have been renamed to begin with “Indication” rather than “Alarm”.
There will be a change in the views in the Panorama application (Table & Graphic Mode) and Pro application (field names in the reports).
For example - “Generator_X.Indication Internal Low Pressure Oil” instead of “Generator_X.Alarm Internal Low Pressure Oil.
Alarms Criticality Changes
“Alarm Galooli Aviation Light Fail” alarm has been changed to “Non-Urgent” criticality.
Grid_Not_Available_Phase X - As the alarm's criticality was "Urgent", it has now been canceled (empty), so it will not affect the number or color of alarms on the tab. An orange dot will be displayed next to the unavailable phase in the "Grid" sub-tab of "Site Status".
New Panorama Alarms Display
Changes have been made to the display logic for alarms in Panorama and Mobile applications three:
Color of the unit in the organization tree
Alarms count on the main card
Alarms count on the sub-card
The following types of alarms "Alarm Galooli"/Active"/"Integrity"/"Critical"/"Urgent"/"Non Urgent"/"Indication":
Will not appear in the sub-cards (in the notification list at the bottom of the card)
The counter will not include them as active alarms
Alarms with “Indication” criticality:
The alarms counter will not include them
The alarms list will be displayed in the sub-card
The units of type Site | Generator | IOT will not be colored blue when there is an active “Indication” level alarms. When there is a more acute alarms - the unit will be colored in the corresponding color (yellow/orange/red), if there is no more acute alarm - the unit will be colored green.
Sub-card alarms display:
Alarms will be sorted according to their severity (high to low).
In the event that there are several alarms of the same severity, they will be ordered alphabetically.
Generator Fails To Start Alarms Improvements
There are two types of alarms for faulty generators, one originating from the generator's panel in the field (Generator X Alarm Internal), the second alarm is caused by the internal logic of Galooli (Site Global Alarm Galooli). For example - Electricity is provided by the grid to the unit, and the generator is also functioning, resulting in the alarm “Generator Fail To Stop”.
In the past when one of the above alarms was activated the corresponding alarm was activated too.
From this version changes have been made to the synchronization between the alarms so that the generator internal alarm (which will appear in the generator card in Panorama application) will trigger the logical alarm (which will appear in the Site Status card in Panorama application), but not the other way around. Consequently, if the logical alarms is “true”, an alarm will appear in Site Status card but will not force an alarm to appear in the generator card (the Internal alarm flag may remain unset).
Table Mode Fleet Basic Information
Upon release of this version, fleet units system data (InfoBead) will be displayed in a table mode of the Panorama Live mode.
Updated Alarms Logic
Several alarms logic have been updated in order to mask irrelevant alarms generated by the site hardware. The new logic will reduce the amount of unnecessary alarms and will allow the focus to be placed on the most important alarm in the various Live Mode cards in the Panorama application.
The following adjustments have been made to the alarms:
Rectifier - “Alarm Galooli Urgent PFA” / “Alarm Galooli Non Urgent PFA” - Disable the alarm from the rectifier if the unit's local time is not between 9:00 and 15:00.
Rectifier - “Alarm Galooli Urgent RFA” / “Alarm Galooli Non Urgent RFA” - Disable the rectifier alarm if there is no AC power at the site at the moment.
Generator - “Alarm Galooli Low Oil Pressure” - Disable alarm If the generator is not running
We have left the original readings from the rectifier/generator under the following fields, however, the severity will be "observation":
“Rectifier_X.Alarm_Internal_Urgent_PFA”
“Rectifier_X.Alarm_Internal_NonUrgent_PFA”
“Rectifier_X.Alarm_Internal_Urgent_RFA”
“Rectifier_X.Alarm_Internal_NonUrgent_RFA”
“Generator_X.Internal_Low_Oil_Pressure”
Generator High Load Power Digital Alarms
New digital alarms have been added to the system:
Alarm Galooli Generator X High Load
This alarm will activate if: Site Global Generator X Load Power/(0.8* Generator X KVA * 1000) > 0.8, AND KVA > 0
Alarm Galooli Generator X Very High Load
This alarm will activate if: Site Global Generator X Load Power/(0.8* Generator X KVA * 1000) > 0.9, AND KVA > 0
There is a dedicated field in the report mechanism for each of the alert.
Read More - Group: Site Global
Site_Global.Alarm Galooli High Battery Current
Site_Global.Alarm Galooli High System Voltage
Read More - https://galooli.atlassian.net/wiki/x/BACSuw
IOT Live Display
IOT type units in the Panorama Live mode now supports all the tabs/cards similar to Site type units, except for the Site Status tab/card, which displays a map instead.
Inverter Card Updates
Updates were made to the inverter card in Panorama Live Mode and the Mobile App story.
A new display support for the AC voltage stabilizer component. Will be displayed If the inverter is configured only for AC data.
Read More - https://galooli.atlassian.net/wiki/x/GwBar
Panorama Table View Changes
Data is now displayed in Panorama table view based on the unit level rather than the layout type of the unit as in the past.
Mobile App
New ATS Meter Story
The Site/IOT units have been updated with a new story called “ATS Meter”.
Read More - https://galooli.atlassian.net/wiki/x/AQCm1Q
Colocation/Tenant Story Display
Changes have been made to the Colocation/Tenant story regarding the presentation of tenant power types. The story will display differently based on the type of tenants on the site; for example, a site with only AC or DC tenants will appear different from one with both AC and DC tenants
Separating the display of tenants to AC and DC tenant due to different billing methods and SLA agreements.
Read More - Colocation/Tenant Story
Session Timeout
A new behavior of the session time was published in the Galooli Mobile App. Unless the user disconnects proactively or 24 hours have passed (the maximum lifetime of a token), the token will remain active, and the user will remain connected. After 24 hours the token will turn invalidated and a new session will start but the user still will remain connected.
IOT Live Display
IOT type units in the Mobile APP now support all the tabs/cards similar to Site type units in Panorama, except for the Site Status tab/card, which displays a map instead.
Generator Story News
The story settings of the generator have been modified.
Even if no panel is configured and Generator Running X = False, a generator story will be displayed if Site Global.Fuel X Configured = TrueX = False, a generator story will be displayed if Site Global.Fuel X Configured = True
Read More - Generator Story
Rectifier Story
The rectifier control story now includes an option to “Reset Rectifier”. Currently, the menu will only be available for the Vertiv M830B NCU rectifier.
Read More - Generator Rectifier Story
Mobile App “Back” Button History
Android users can now skip to the history of stories they have viewed in the mobile app. The "back" button is used to do this.
Users can return to the last story they visited by clicking the "back" button.
Pro Application
New AI-Based Reports Type
The Galooli Pro application now includes a new type of report based on artificial intelligence.
By integrating many parameters into one report, Galooli AI-Based Reports offer real value to the user by providing conclusions and suggestions for action based on a summary of the data.
There are several groups of fields as part of the AI-Based reports:
AI-Based Analysis - Grid
AI-Based Analysis - Overall Efficiency
AI-Based Analysis - Fuel
AI-Based Analysis - Generators
AI-Based Analysis - Battery
Read More - AI-Based Reports
New AI-Based SDK Request Report
In addition to the creation of the new AI-based reports, the SDK tool now includes the ability to retrieve data from AI fields as well.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2812936270/Request+Methods#AI-Based-Report
Schedule Dashboards & Reports News
Three new updates related to the Schedule Dashboards & Reports tool:
The schedule dashboard Schedule dashboards and reports will only be sent to Galooli users' email addressesusers with active access to Galooli Solution.
The address list section has a limit of 20 e-mail addresses. If you wish to schedule the report to be sent to more than 20 email addresses, please create a rule in your email platform that will forward the schedule. report to other email addresses (Outlook/Gmail).
A dashboard/report attached to an email cannot exceed 7.5MB in size. Attached files that exceed the size limit will be attached as download link (directly from the cloud). - It has been updated since 3/8/24
Dashboard Designer New Component
The Dashboard Designer now includes an additional component to the "Card" item called "Icon".
The icon component allows you to highlight the meaning of the value displayed on the card (whether positive or negative).
Read More - Card Item
New Building - Global Summary Fields
The summary reports now include a new field section: “Building - Global”.
The "Building - Global" summary group tracks external temperature and humidity averages, energy consumption for heating, hot water, CHP, grid, and solar, as well as gas usage, including boilers and CHP systems.
Read More - Building - Global Fields
Scheduled Reports SFTP Support
The scheduled reports/dashboard option has been enhanced to support SFTP as of 21/7/24. This new enhanced support is part of an existing feature of the FTP service that enables organizations to upload files to a server. Individuals with access to the server may view the files. Using this tool, multiple emails can be added to the address list of the scheduled reports/dashboard wizard in one operation if your organization uses "FTP Services".
FTP is the traditional file transfer protocol and SFTP (or Secure File Transfer Protocol) is an alternative to FTP that also allows you to transfer files, but adds a layer of security to the process.
Dashboard Designer Item Menu
The Dashboard Designer has been improved with a separate action menu for each item, which includes additional actions based on its type.
Dashboard Designer Filters Update
The logic for the “Days Before Report End” filter in the dashboard designer has been updated so that the last day (Days Before Report End = 0) in the report that includes the date of the same day the report is executed will be the day before.This is due to the fact that the summary data for the execution day will only be calculated the following day.
Read More - https://galooli.atlassian.net/wiki/x/EoDjqg
Maximum Size For PDF Format
If a user attempts to export a PDF document or schedule a report that includes a PDF document whose file size is bigger than 2000 x 20 cells, the export button will be disabled (marked with a red dot). A message explaining the reason for the deactivation will be displayed when the user hovers over the execute button.
Export PDF | Schedule PDF |
---|---|
Fields Name Display
Fields whose display name is changed by the IO’s mechanism will be displayed in a different font (italic) and will display the original field name in multitype when hovered over by the user.
New SDK Service Log Support
The new SDK Service Log Support will be available in this version, allowing you to view changes made to summary fields data through the service log tool.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2812936270/Request+Methods#Service-Log-Report
New Calculated Fields Functions
The calculated fields mechanism has been enhanced with two new functions:
“TO HOURS” function
Converts a time span object to a numeric value which presents the number of hours.
“TO DAYS” function
Converts a time span object to a numeric value which presents the number of days.
Site Global New Analog and Summary Fields
Two new analog Site Global fields have been added to the report mechanism:
Site Global AC Tenants Load Power [W]
Site Global DC Tenants Load Power [W]
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3024584866/Active+Recorded+Analog+Inputs#Site-Global
Therefore, new summary fields have been added accordingly:
DC Tenants Load - Power Max/Min/Avg [kW]
DC Tenants Load - Total Energy [kWh]
AC Tenants Load - Power Max/Min/Avg [kW]
AC Tenants Load - Total Energy [kWh]
Read More - https://galooli.atlassian.net/wiki/x/BQCQqg
Rectifier Used Load Field Changes
The field “Rectifier_X.Used_Load” name has been changed to “Rectifier_X.Used_Capacity”. Additionally, the calculation method for the field has been modified.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3024584866/Active+Recorded+Analog+Inputs#Rectifier
New Rectifier Table Description Fields
The field allows to the organization to identify the x-ray table associated with a particular unit. The field name is “Rectifiers.Rectifirer X Table Description”.
Read More - X-Ray Group
Automation Execution Objects
From this version onwards, the user may save a larger group of individual units for automation by increasing the field's character limit from 150 to 500. If the user exceeds the allowed number of characters (500), an error message will appear.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2844917783/Automation+Editor#General-Functions
My Automations: Rectifier Reset Command
We have added support for sending a command to reset the rectifier as part of the automation mechanism.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2844917783/Automation+Editor#Send-Unit-Command
Manager Application
Unit/Group/Cluster Events Destination Emails
A destination email generated by an event in the Galooli solution is only send to Galooli users to ensure data security.
New Auto-Logout Options
Beginning with the next version, any downgrade level of configurations/permissions will result in automatic ending of the user's session and disconnection from the system (Galooli solution and Mobile Application).
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2723872777/Galooli+Solution#Auto-Logout
New Update Sync Functionality
An update sync mechanism has been added to prevent situations where one user's edit overrides another user's edit (when both users edit the same unit or object at the same time).
All of the following modules in Galooli Manager Application will be affected by this mechanism:
My Assets
My Calibrations
My Contacts
My Geofences
My Units
My Users
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/edit-v2/2572877825#Update-Sync-Functionality
All Organization Option
Starting with this version, only Galooli administration users will be able to use the "All Organization" selection option. Other type of users may still be able to login to multiple organizations via the second option called "Select All", which allows them to select organizations one by one or select them all.
The difference between the two methods is that when the "All Organization" option is used, it allows for the automatic addition of future organizations without the need for manual intervention.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2584182813/Permission+Management#Organizations-Permission
All Organizations Option (Admin) | Select All Option (Galooli/Manager/User) |
---|---|
Analog & Temperature Events
It will now be possible to set negative thresholds for "Analog" and "Temperature" events.
Read More - Events
Digital Inputs Changes
The following changes have been made to the digital inputs in the system:
Removed Inputs | Changed Inputs |
---|---|
DC_Status_BLV DC_Status_PLD DC_Status_LVD Rectifier_X.Alarm_Smoke Rectifier_X.I_Battery_Value_Available Alarm_Huawei_AC_Failure Alarm_Huawei_DC_Overvoltage Alarm_Huawei_DC_Undervoltage Rectifier_X.Alarm_Common_DryContact_Reserved Alarm_Common_EOV_Over_Voltage | Alarm_Common_Mains_Failure >> Alarm_Internal_Mains_Failure Alarm_Common_Under_Voltage_1 >> Alarm_Internal_LVD Alarm_Common_Under_Voltage_2 >> Alarm_Internal_PLD Alarm_Common_System_Fault >> Alarm_Internal_HW_failure Alarm_Common_Battery_Observation >> Alarm_Internal_Batter Alarm_Common_Rectifier_Fail >> Alarm_Internal_Rect_Fault Alarm_Common_SOB_Site_On_Battery >> Alarm_Internal_Discharge Alarm_Common_LVD_Low_Voltage_Deferred >> Alarm_Internal_LVD Alarm_Common_LVP_Low_Voltage_Prompt >> Alarm_Internal_PLD |
Organizational KPI
The upcoming version will introduce some changes to Organizational KPIs:
A new section has been added, called: “Consumers”
Under this section, a new field has been added, called: “High Consumers Power Threshold”
The field “Current Threshold Site Down” moved from “Global DC” section to the new “Consumers” section.
The following fields have been added to the “Global DC” section:
“High System Voltage Threshold” field
“High Battery Current Threshold” field
“Grid” section now includes a new field called: “High Current Threshold” field.
The new fields have also been added to the report mechanism under the sections “Unit KPI” and “Organizational KPI”.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2802450433/My+Units#Organizational-Information
Removed Digital Fields
The following digital fields have been removed:
DryContact_Grid_On_Load
DryContact_Generator1_OnLoad
DryContact_Generator2_OnLoad
Login Report Changes
Changes and improvements are made to the login report of the users of the organization.
Rear More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2580447265/My+Users#Login-Report
New Meters Support
With this version, we will support up to 12 different meters for each unit.
X-Ray Parameters: DG Fields Rename
A change has been made to the names of the fields dealing with the generator in X-Ray Parameters (under the configuration tab on the unit edit screen).
The following fields have been changed:
Rectifiers 1-5:
DG Off Current → Generator Off Current
DG Off Voltage → Generator Off Voltage
DG Off Voltage 2 → Generator Off Voltage 2
DG On Voltage → Generator On Voltage
NOC Application
New Alarm Display (Focused View)
In this version of the NOC application, we have adjusted the NOC alarms tab display to focus only on active alarms. This means that organizations with a large number of configured alarms will be able to view all the relevant alarms in one column called "Active Alarms," thereby simplifying the display of alarms.
New Alarms
The NOC alarms list has been updated with a new alarms:
Power - AC Meter Grid Low PF (Power Factor)
Power - Generator Running and Battery Not Charging
Power - Generator Running > 3 hours
Power - Battery High Current
Power - High System DC Voltage
Power - Consumers Load High
Power - Grid High Current
Generator - High Load Power
Generator - Very High Load Power
Generator - Charge Alternator Fail
Generator - Battery High
Generator - Low Coolant
Generator - Door Open
Generator - Under Frequency
Rectifier - Battery Door Open
Rectifier - AC Surge Protector Fault
Rectifier - DC Surge Protector Fault
Rectifier - Surge Protector Fault
Fuel - High Level
Hardware - AC Meter Grid Disconnected
Hardware - Output Active
Hardware - Backup Low Voltage
Following alarms logic have been updated:
Rectifier - Temperature High
Power - Consumers Load Drop
Hardware - Power Supply Failure
Read More - NOC Alarms List
New Masking Device Irrelevant Alarms
Masking irrelevant alarms will be implemented in the NOC in the same manner as it is in the Panorama application.
Apps Application
Grid Usage Report
The Grid Usage Report now includes a new “Tenant Site ID” field.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3314091159/Grid+Usage+Report#Report-Content
Fleet Application
Geofences Display
As part of the next version of the Fleet Application, a fix will be released to enable the display of geofences when the user hovers over it.
General Updates
Support Tool Improvements
The Galooli Support tool has undergone several significant improvements:
Allows pasting screenshots (including those copied from the clipboard) that will be automatically added to the attachment section.
An option to close/reopen tickets.
And more…
Read More - Galooli Support
New Galooli Academy Article
New academy article about “Galooli Colocation Solutions” is now available for you.
Read More - https://galooli.atlassian.net/wiki/x/AQAS0
Sparta Lead-Acid Installation & Configuration Article
New academy article about “Sparta Lead-acid Installation & Configuration” is now available for you.
Read More - Sparta Installation and Configuration
New Software Overview Videos
New Galooli software overview video regarding the X-Ray tool is now available.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/edit-v2/2455208477#Galooli-X-Ray-Tool-OverviewNew French version software overview video regarding the Panorama Application is now available.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2455208477/Webinars+Videos#Galooli-Panorama-Application-Overview---French-Version
New “How to” Article
Check out Galooli's new "How to" article titled, “How to check new alarms integrations?”
Read More - https://galooli.atlassian.net/l/cp/MAQ7Q0Ta
Product Terms Of Use
Galooli Solution now includes a link to the "Product Terms Of Use" under the "About" section.
New Hardware Integrations & Support
Omnicomm LLS 4 series
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2429617277/Omnicomm+LLS#LLS-4-Series
External DC Power Supply
Read More - External AC to DC Power Supply
Saltec AC Stabilizer Inverter
Read More - Saltec AC Stabilizer Inverter
Cummins Generator Panel new model support - PSO600
Read More - Cummins
Megmeet MegaPower MC2600 new rectifier support
Read More - Megmeet
DSE Generator Panel new model support - 8610MK2
Read More - https://galooli.atlassian.net/l/cp/EWe9cwLC
Eaton new rectifier support
Read More - Eaton
Polarium SNMP Integration
From now on Galooli support Polarium smart batteries SNMP integration. Polarium smart batteries can be read via SNMP by utilizing the rectifier (currently supported by Delta and CFX).
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2562097153/Polarium+Batteries#Polarium-(SNMP)
SolarEdge Inverter API Integration
From now on Galooli can receive data from the SolarEdge Inverter via API.
Galooli Solution Applications URL Changes