The latest version of the Galooli solution incorporates features that reflect our open dialogue with our customers and Galooli's desire to facilitate and improve the system's use. The purpose of this article is to provide information about the main features of this version.

General Updates

Updated Articles

New Hardware Support and Integration

Logout Mid-Session New Error Message

A new error message has been added to the system to notify the user when they are disconnected due to simultaneous connections from two stations/browsers using the same user account.

image-20241215-082245.png

New Humidity Sensor Support

Starting from the upcoming version, humidity sensor support will be introduced for Shelter 1-4. This enhancement will be reflected across various Galooli Solution applications, including:

  • Panorama Application Live View for real-time humidity data visualization.

  • Manager Application for configuration and KPI definition.

  • NOC Application

  • Mobile Application

image-20250105-122931.png

Panorama Application

Trends In Live View

The new Panorama Live View feature, “Live View Trends,” provides real-time insights directly within the live view. This enables users to assess site performance without proactively running reports or dashboards. The feature highlights whether current production and consumption levels align with historical data patterns or deviate from them, helping to identify normal or abnormal behavior.

In this version, the Trends are relevant only to “Solar” data and “Consumers Load”.

Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2891251716/Site+Status+Card#Site-Trends

image-20250105-105933.png

X-Ray Tab

Starting with this version, the Panorama Live mode revolutionizes how users interact with X-Ray data by presenting it in one clear, intuitive, and user-friendly location. The new X-Ray tab takes the user experience to the next level, offering powerful features that make insights clearer, more interactive, and immediately actionable.

A standout enhancement is the ability to effortlessly initiate manual X-Ray requests—bypassing the standard automatic mechanism—empowering users with greater flexibility and control like never before. Additionally, the tab dynamically highlights invalid settings directly within the site's live view, delivering real-time insights and actionable feedback that streamline decision-making and optimize operations.

Read More - https://galooli.atlassian.net/l/cp/kVrS5QJm

image-20241231-115101.png

New Grid Insights Dashboard

The new Grid Insights Dashboard provides comprehensive analysis and monitoring of grid energy consumption and efficiency.

Key features include:

  • Insights into phases balancing, including load and voltage trends, to identify and address imbalances.

  • Detailed metrics on peak hour usage, comparing grid energy consumption during peak and off-peak hours, and identifying potential inefficiencies.

  • Recommendations for corrective actions, such as executing configuration adjustments using the X-Ray tool.

  • Visual trends to track minimal load balance and grid usage patterns over time, enabling data-driven optimization.

This dashboard empowers users to enhance grid performance by offering actionable insights and tools for efficient energy management.

Read More - Unit Level Dashboard / Multi Unit Level Dashboard

Picture - TBA

Smart Battery Fields Precision

The number of digits displayed after the decimal point has been changed to 2 for the following fields under Smart Batteries (1-20):

  • Min Cell V

  • Max Cell V

The change is reflected in Panorama Live Mode and the Mobile Application.

Mobile Application

X-Ray Story

With the recent addition of the X-Ray tab viewing capability in the Panorama application, further enhancements have been made to the X-Ray Story in Galooli's mobile application. This update provides an improved and seamless experience for viewing the upgraded table and utilizing the “Scan” capability,

Read More - https://galooli.atlassian.net/wiki/x/QoBDlg

image-20241231-115611.png

Pro Application

New Summary & Updates

  • Grid Outage Count (Summary type - Energy Global)

This field will calculate the number of occurrences (relative to the report period and aggregation) where the “Site_Global.Alarm Galooli Grid Fail” field changed from 'No' to 'Yes'.

Read More - https://galooli.atlassian.net/wiki/x/BQCQqg

  • Rectifier Fields (Summary type - Rectifiers)

    • “Rectifier 1 - Solar Module X Output Power Max [kW]”

    • “Rectifier 1 - Solar Module X Output Power Avg [kW]”

    • “Rectifier 1 - Solar Module X V Max/Avg” renamed to "Rectifier 1 - Solar Module X Input Voltage Max/Avg"

    • “Rectifier 1 - Solar Module X I Max/Avg” - renamed to "Rectifier 1 - Solar Module X Output Current Max/Avg"

Read More - Rectifiers Fields

  • Generator X Ignition Count - Update Logic (Summary type - Working Generators)

The ignition counter will increase whenever there is a change in the status of "Site Global Generator X Running" from false in the previous record to true in the current record. However, any records where "Site Global Generator X Running" is false and "Generator X Disconnected" is true will be ignored when performing this calculation.

  • Grid Tariff Time Periods (New group)

    • Battery Charge Time by Grid - Peak Hours

    • Battery Charge Time by Grid - Off Peak Hours

    • Battery Charge Time by Grid - Shoulder Hours

Read More - Grid Tariff Time Periods

New AI Fields & Updates

  • AI Based Analysis Grid (AI Based)

    • Unstable Grid - Active/Description/Activation Date

    • Imbalanced Grid Phases - Active/Description/Activation Date

    • Grid Peak Hours Inefficient Usage - Active/Description/Activation Date

Read More - https://galooli.atlassian.net/wiki/x/CABV0Q

Fuel Tank 1-2 Fields Changes

Updates and additions to the Fuel fields:

Changes to existing fields:

  1. “Main Fuel Tank Capacity” renamed to “Fuel Tank 1 Capacity”

  2. “Main Fuel Tank Minimum Level” renamed to “Fuel Tank 1 Minimum Level”

  3. “Main Fuel Calibration” renamed to “Fuel Tank 1 Calibration Name”

  4. “Main Fuel Tank Capacity N” renamed to “Fuel Tank 1 Capacity N”

  5. “Main Fuel Tank Minimum Level N” renamed to “Fuel Tank 1 Minimum Level N”

Calculation logic for the above fields:
a. If infoBeadFleetBasic exists: Fleet Basic Fuel Main (infoBeadFleetBasic.eAnalogInfo.Fuel_Main).
b. Otherwise: Site Global Fuel 1.

New fields added, based on Site Global Fuel 2:

  1. Fuel Tank 2 Capacity

  2. Fuel Tank 2 Minimum Level

  3. Fuel Tank 2 Capacity N

  4. Fuel Tank 2 Minimum Level N

  5. Fuel Tank 2 Calibration Name

The new fields represent the values derived from a calibration table linked to the IO that connected to the unit.

Lithium Ion Battery Field Name Updates

Changes to Lithium Ion Batteries (LIB) fields names across the Galooli system (My X-Ray | Pro | My Units)

  • The field “Module #X” has been renamed to “Module Version”.

  • The field “SerialNumber” has been renamed to “Serial Number”.

  • The “LIB” prefix has been removed from the field names displayed in the X-Ray table.

Galooli Automations - Control Commands Permissions

A new permissions verification mechanism has been implemented for the Automations tool.
If an automation is triggered by a user lacking the Control Commands permission and includes a command from the designated command list, the automation will fail execution.

During a script Verify process, the code will "break," and an error message will be displayed to the user.

Read More - https://galooli.atlassian.net/l/cp/11TasXKx

image-20241203-074254.png
image-20241203-074211.pngimage-20241203-074230.png

“Status” Field Changes

We have removed several options from the filtering details of the field “Status”:

  • Alert

  • Unknown

  • Upgrade Process

image-20241209-091940.png

NOC Application

Shelter Alarms Changes

NOC environment alarms have undergone several changes, including:

  1. Updated Alarm Names: Renamed alarms to improve clarity and alignment with the system's terminology.

  2. Individual Shelter Alarms: Introduced distinct alarms for each shelter (Shelters 1, 2, 3, and 4) for better specificity and monitoring.

Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2605350930/NOC+Alarms+List#Environment-Alarms

Manager Application

Humidity Sensor Configuration

Starting from the upcoming version, we will offer support for a humidity sensor (for Shelter 1-4).

Configuration:

  • The sensor configuration can be done in the configuration tab within the unit editing window (My Units).

  • The humidity sensor will appear in the expansion tab for Shelter 1-4 after the unit's next transmission.

image-20241219-094834.png

Thresholds:

A threshold for a humidity alarm (Non-Urgent level) can be configured under KPI → Environment Section in the unit editing window.

image-20241219-094953.png

Additionally, a corresponding field has been added to the Organizational KPI, with a default value of 80%.

The Galooli Humidity High Alarm will be triggered if:

  • Humidity Configured = True

  • Humidity > KPI

  • KPI ≠ 0 (not zero).

Audit Trail - OTA Logs

Over-the-air (OTA) action logs are now documented and visible in the Audit tool, available in the Galooli Solution.

Read More - Audit

image-20250105-121506.png

IOs Invert State & Panic Display

The checkboxes “Invert State” and “Panic” will only be displayed to the user when the IO is of type Digital and configured as an Input (Digital 1–50). In all other cases, these checkboxes will not be shown.

Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2830401910/IO+s#IO%E2%80%99s-Creation

X-Ray KPIs & My X-Ray Filter Default State

The default filtering configuration for the X-Ray tables and the X-Ray KPIs component under the Unit Configuration in My Units has been updated. The new default will display only rows with values. This filter can be toggled on and off using the following button.

Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3094183938/X-Ray+KPIs#X-Ray-Parameters / https://galooli.atlassian.net/wiki/spaces/KP/pages/2915762177/My+X-Ray#X-Ray-Table-Configuration-Section

X-Ray KPIs

My X-Ray

image-20241209-094444.pngimage-20241209-094405.png

Sub-Menu Name Change

The sub-menu/tab previously named "Installation Setups" under the Configuration Menu has been renamed to "Setups." Following this change, the configuration process for Video Streamers supported by Galooli will now be carried out here.

Read More - https://galooli.atlassian.net/l/cp/ia0MJPEp

image-20250105-121902.png

My Calibrations - Improve Descriptions

  • Display Adjustments:

    • For calibration types: “Box”, “Cylinder horizontal”, “Capsule horizontal”, “Cylinder vertical”, and “Capsule vertical”

      • Empty has been renamed to Empty-N.

      • Full has been renamed to Full-N.

      • For the fields W/L/H/R, the unit [m] has been added next to each field (e.g., R [m]).

    • For calibration type Table:

      • Source has been renamed to Source-N.

  • Max Value Calculation for All Calibration Types:

    • The Max Value will now be calculated only after saving the calibration (both when creating or editing a calibration).

    • A notification will be displayed to the user: "Save to show max."

My Calibrations - Removed Calibration Types

Two calibration types have been removed from the Calibration Type menu in My Calibrations within the Manager application:

  1. Thermistor_NTC

  2. Polynomial Calibration

image-20241215-082856.png

Shelters Support

We have removed support for configuring more than four Shelters per unit.