The latest version of the Galooli solution incorporates features that reflect our open dialogue with our customers and Galooli's desire to facilitate and improve the system's use. The purpose of this article is to provide information about the main features of this version.
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
General Updates
Updated Articles
New FAQ article - Where does Galooli operate SIM cards?
Updated Galooli Training Programs Policy
New Academy Lesson - https://galooli.atlassian.net/wiki/x/AQAe4Q
New Ultragate Tray Cabinet - https://galooli.atlassian.net/wiki/x/mYDssQ
Sparta Lead Acid Gateway New Version (4.18) - https://galooli.atlassian.net/l/cp/Ac16hCof
Sparta Lithium-ion Gateway New Version (2.15) - https://galooli.atlassian.net/l/cp/dAeBV14JNew Enersys Rectifier Model Support (SFX_MCU2) - https://galooli.atlassian.net/l/cp/MsQR9iV8
New Hardware Support and Integration
Dahua DH-IPC Network Camera - New integration
CBEIL PTZ Network Camera - New network camera support and new integration
New Enersys Rectifier Model Support (SFX_MCU2) - https://galooli.atlassian.net/l/cp/MsQR9iV8
Logout Mid-Session New Error Message
A new error message has been added to the system to notify the user when they are disconnected due to simultaneous connections from two stations/browsers using the same user account.
New Humidity Sensor Support
Starting from the upcoming version, humidity sensor support will be introduced for Shelter 1-4. This enhancement will be reflected across various Galooli Solution applications, including:
Panorama Application Live View for real-time humidity data visualization.
Manager Application for configuration and KPI definition.
NOC Application
Mobile Application
Panorama Application
Trends In Live View
The new Panorama Live View feature, “Live View Trends,” provides real-time insights directly within the live view. This enables users to assess site performance without proactively running reports or dashboards. The feature highlights whether current production and consumption levels align with historical data patterns or deviate from them, helping to identify normal or abnormal behavior.
In this version, the Trends are relevant only to “Solar” data and “Consumers Load”.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2891251716/Site+Status+Card#Site-Trends
X-Ray Tab
New Platinum license capability has been added to Starting with this version, the Panorama Live Mode called “X-Ray Tab”.The mode revolutionizes how users interact with X-Ray data by presenting it in one clear, intuitive, and user-friendly location. The new X-Ray card/tab introduces enhanced capabilities designed to provide a clearer and more interactive user experience. The tab allows users to tab takes the user experience to the next level, offering powerful features that make insights clearer, more interactive, and immediately actionable.
A standout enhancement is the ability to effortlessly initiate manual X-Ray requests effortlessly and requests—bypassing the standard automatic mechanism—empowering users with greater flexibility and control like never before. Additionally, the tab dynamically highlights invalid settings directly within the site's live view, offering delivering real-time insights and actionable feedback that streamline decision-making and optimize operations.
Read More - https://galooli.atlassian.net/l/cp/kVrS5QJm
New Grid Insights Dashboard
The new Grid Insights Dashboard provides comprehensive analysis and monitoring of grid energy consumption and efficiency.
Key features include:
Insights into phases balancing, including load and voltage trends, to identify and address imbalances.
Detailed metrics on peak hour usage, comparing grid energy consumption during peak and off-peak hours, and identifying potential inefficiencies.
Recommendations for corrective actions, such as executing configuration adjustments using the X-Ray tool.
Visual trends to track minimal load balance and grid usage patterns over time, enabling data-driven optimization.
This dashboard empowers users to enhance grid performance by offering actionable insights and tools for efficient energy management.
Read More - Unit Level Dashboard / Multi Unit Level Dashboard
Picture - TBA
Smart Battery Fields Precision
The number of digits displayed after the decimal point has been changed to 2 for the following fields under Smart Batteries (1-20):
Min Cell V
Max Cell V
The change is reflected in Panorama Live Mode and the Mobile Application.
Mobile Application
X-Ray Story
With the recent addition of the X-Ray tab viewing capability in the Panorama application, further enhancements have been introduced made to the X-Ray Story in Galooli's mobile application, providing . This update provides an improved and seamless experience for viewing the upgraded table .and utilizing the “Scan” capability,
Read More - https://galooli.atlassian.net/wiki/x/QoBDlg
Pro Application
New Summary
Fields& Updates
A new summary fields have been added to the Galooli reports system:
“Grid Outage Count” - Grid Outage Count (Summary type - Energy Global)
This field will calculate the number of occurrences (relative to the report period and aggregation) where the “Site_Global.Alarm Galooli Grid Fail” field changed from 'No' to 'Yes'.
Read More - https://galooli.atlassian.net/wiki/x/BQCQqg
Rectifier Fields (Summary type - Rectifiers)
“Rectifier 1 - Solar Module X Output Power Max [kW]”
“Rectifier 1 - Solar Module X Output Power Avg [kW]”
“Rectifier 1 - Solar Module X V Max/Avg” renamed to "Rectifier 1 - Solar Module X Input Voltage Max/Avg"
“Rectifier 1 - Solar Module X I Max/Avg” - renamed to "Rectifier 1 - Solar Module X Output Current Max/Avg"
Read More - Rectifiers Fields
“Generator Generator X Ignition Count” Count - Update Logic:
Add an ignition to the counter if(Summary type - Working Generators)
The ignition counter will increase whenever there is a change in the status of "Site Global Generator X Running
was" from false in the previous record
, andto true in the current record
(state changed from false to true)Ignore. However, any records where "Site Global Generator X Running" is false
ANDand "Generator X Disconnected" is true will be ignored when performing this calculation.
Grid Tariff Time Periods (New group)
Battery Charge Time by Grid - Peak Hours
Battery Charge Time by Grid - Off Peak Hours
Battery Charge Time by Grid - Shoulder Hours
Read More - Grid Tariff Time Periods
New AI Fields & Updates
AI Based Analysis Grid (AI Based)
Unstable Grid - Active/Description/Activation Date
Imbalanced Grid Phases - Active/Description/Activation Date
Grid Peak Hours Inefficient Usage - Active/Description/Activation Date
Read More - https://galooli.atlassian.net/wiki/x/CABV0Q
Fuel Tank 1-2 Fields Changes
Updates and additions to the Fuel fields:
Changes to existing fields:
“Main Fuel Tank Capacity” renamed to “Fuel Tank 1 Capacity”
“Main Fuel Tank Minimum Level” renamed to “Fuel Tank 1 Minimum Level”
“Main Fuel Calibration” renamed to “Fuel Tank 1 Calibration Name”
“Main Fuel Tank Capacity N” renamed to “Fuel Tank 1 Capacity N”
“Main Fuel Tank Minimum Level N” renamed to “Fuel Tank 1 Minimum Level N”
Calculation logic for the above fields:
a. If infoBeadFleetBasic
exists: Fleet Basic Fuel Main (infoBeadFleetBasic.eAnalogInfo.Fuel_Main
).
b. Otherwise: Site Global Fuel 1.
New fields added, based on Site Global Fuel 2:
Fuel Tank 2 Capacity
Fuel Tank 2 Minimum Level
Fuel Tank 2 Capacity N
Fuel Tank 2 Minimum Level N
Fuel Tank 2 Calibration Name
The new fields represent the values derived from a calibration table linked to the IO that connected to the unit.
Lithium Ion Battery Field Name Updates
Changes to Lithium Ion Batteries (LIB) fields names across the Galooli system (My X-Ray | Pro | My Units)
The field “Module #X” has been renamed to “Module Version”.
The field “SerialNumber” has been renamed to “Serial Number”.
The “LIB” prefix has been removed from the field names displayed in the X-Ray table.
Galooli Automations - Control Commands Permissions
A new permissions verification mechanism has been implemented for the Automations tool.
If an automation is triggered by a user lacking the Control Commands permission and includes a command from the designated command list, the automation will fail execution.
During a script Verify process, the code will "break," and an error message will be displayed to the user.
Read More - https://galooli.atlassian.net/l/cp/11TasXKx
“Status” Field Changes
We have removed several options from the filtering details of the field “Status”:
Alert
Unknown
Upgrade Process
Fuel Tank 1-2 Fields Changes
Updates and additions to the Fuel fields:
Changes to existing fields:
“Main Fuel Tank Capacity” renamed to “Fuel Tank 1 Capacity”
“Main Fuel Tank Minimum Level” renamed to “Fuel Tank 1 Minimum Level”
“Main Fuel Calibration” renamed to “Fuel Tank 1 Calibration Name”
Calculation logic for the above fields:
a. If infoBeadFleetBasic
exists: Fleet Basic Fuel Main (infoBeadFleetBasic.eAnalogInfo.Fuel_Main
).
b. Otherwise: Site Global Fuel 1.
New fields added, based on Site Global Fuel 2:
Fuel Tank 2 Capacity
Fuel Tank 2 Minimum Level
NOC Application
Shelter Alarms Changes
NOC environment alarms have undergone several changes, including:
Updated Alarm Names: Renamed alarms to improve clarity and alignment with the system's terminology.
Individual Shelter Alarms: Introduced distinct alarms for each shelter (Shelters 1, 2, 3, and 4) for better specificity and monitoring.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2605350930/NOC+Alarms+List#Environment-Alarms
Manager Application
NewHumidity Sensor
SupportConfiguration
Starting from the upcoming version, we will offer support for a humidity sensor (for Shelter 1-4).
Configuration:
The sensor configuration can be done in the configuration tab within the unit editing window (My Units).
The humidity sensor will appear in the expansion tab for Shelter 1-4 after the unit's next transmission.
Thresholds:
A threshold for a humidity alarm (Non-Urgent level) can be configured under KPI → Environment Section in the unit editing window.
Additionally, a corresponding field has been added to the Organizational KPI, with a default value of 80%.
The Galooli Humidity High Alarm will be triggered if:
Humidity Configured = True
Humidity > KPI
KPI ≠ 0
(not zero).
Audit Trail - OTA Logs
The logs of overOver-the-air (OTA) actions action logs are now documented and displayed visible in the Audit tool. The feature is already , available in the Galooli Solution.Additionally, logs have been added to the Audit system for actions performed by users through various Unit Command menus in both Panorama and Mobile App.
Read More - Audit
IOs Invert State & Panic Display
The checkboxes “Invert State” and “Panic” will only be displayed to the user when the IO is of type Digital and configured as an Input (Digital 1–50). In all other cases, these checkboxes will not be shown.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2830401910/IO+s#IO%E2%80%99s-Creation
X-Ray KPIs & My X-Ray Filter Default State
The default filtering configuration for the X-Ray tables and the X-Ray KPIs component under the Unit Configuration in My Units has been updated. The new default will display only rows with values. This filter can be toggled on and off using the following button.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3094183938/X-Ray+KPIs#X-Ray-Parameters / https://galooli.atlassian.net/wiki/spaces/KP/pages/2915762177/My+X-Ray#X-Ray-Table-Configuration-Section
X-Ray KPIs | My X-Ray |
---|---|
Sub-Menu Name Change
The sub-menu/tab previously named "Installation Setups" under the Configuration Menu has been renamed to "Setups."
Following this change, the configuration process for Video Streamers supported by Galooli will now be carried out here.
Read More - https://galooli.atlassian.net/l/cp/ia0MJPEp
My Calibrations - Improve Descriptions
Display Adjustments:
For calibration types: “Box”, “Cylinder horizontal”, “Capsule horizontal”, “Cylinder vertical”, and “Capsule vertical”
Empty has been renamed to Empty-N.
Full has been renamed to Full-N.
For the fields W/L/H/R, the unit [m] has been added next to each field (e.g., R [m]).
For calibration type Table:
Source has been renamed to Source-N.
Max Value Calculation for All Calibration Types:
The Max Value will now be calculated only after saving the calibration (both when creating or editing a calibration).
A notification will be displayed to the user: "Save to show max."
My Calibrations - Removed Calibration Types
Two calibration types have been removed from the Calibration Type menu in My Calibrations within the Manager application:
Thermistor_NTC
Polynomial Calibration
Shelters Support
We have removed support for configuring more than four Shelters per unit.