Name - Free text. Provide a name that will help to detect and identify the input
Input - The internal name of the Input in the system
Calibration (Analog only) - In Galooli solutions, calibration is performed by adding a calibration table. To translate data into figures that can be analyzed and deciphered by the user, the table must be attached to the relevant input. Calibration tables should be created previously via the "My Calibrations” menu.
Display Text (Digital and output only) - The format in which the data will be displayed in the systemShow On Map - Select to display the input values in the data box on the map (The green data box)Panorama Unit Live Overview IO’S card
Show on Dashboard - Select to display the input values in the Live Display menu (ZonMax)
Percentage Display (Analog only) - Display values as percentages (In the green data box)
Invert State (Digital and output only) - Invert input to an opposite logical value. Relevant mostly for sensors.Main Fuel Tank (Analog only) - Indicate if the input measures the main fuel tank. If there is one fuel tank. Always select this option. If there is more than one fuel tank, select this option only for the aggregated one.
Panic (Digital only) - This will enable the Panic Button function. Units that are fitted with panic buttons will trigger an event upon pressing the button.
Immobilizer (Output only) - Identifies the output as belonging to the immobilizer function. This function will enable remote immobilization of the unit
...