Welcome to the troubleshooting guide for optimizing energy efficiency and monitoring with our hardware and software solutions. As a leader in the field of energy management, we understand the importance of maintaining peak performance to maximize savings and minimize environmental impact.

This guide is a compilation of challenges our system users are facing and our recommendations how to identify and resolve those issues.

These troubleshooting's are primarily focused on software issues; for hardware-focused troubleshooting's, please refer to the hardware articles. Gateway Solutions / Sensors & Accessories

Offline Units

How to Detect the Fault?

Troubleshooting Steps

It appears that all the units in the organization tree are disconnected. Disconnected units are displayed in gray color.

image-20240411-083407.pngimage-20240411-083226.pngimage-20240411-083555.png
  1. In case not all of the units are disconnected, it is not a Galooli system failure and most probably related to a local network issue.

  2. If all the units in the organization tree are disconnected it can be one of the two:

    • Galooli system failure.

    • Local network issues.

  3. First step is to verify that the local network is up:

    • Check with your communication provider if there is a known issue.

    • Use a different communication provider in one of the units or in a test unit, if the unit is communicating with Galooli’s cloud then the issue is local.

4. In case even after testing with a different communication provider there is no communication escalate the issue to Galooli. Galooli Support

Internet Service Provider Blocking Galooli Solution

How to Detect the Fault?

Troubleshooting Steps

In an attempt to open the Galooli solution, an error is displayed.

image-20240522-080647.png

  1. Check the quality of your internet connection

  2. Change the internet provider company and try opening the Galooli solution again

  3. If the previous step did not work for you or if you do not have a second internet provider, you may wish to clear the DNS cache.

Summary Report With No Values

How to Detect the Fault?

Troubleshooting Steps

Whenever a summary report that should logically display data is run, the displayed data is zero.

image-20240606-102925.png
  1. To determine the specific day when the issue occurred, run the same summary report with the “Data Aggregation” set to "daily".

  2. Following the identification of a problematic day, you should prepare a detailed report on a particular day and specific unit. A detailed field must be located on which the summary field that returned the result 0 in the original report was based.
    To determine which summary field is based on which detailed field, please refer to this link.

  3. In the event that there is data in the detailed report but not in the summary, please open a ticket with the specific example and specify whether it is a specific unit/group of units or the entire organization as well as whether it is one summary field, multiple summary fields, or all summary fields.

Galooli Solutions Passwords Cannot Be Reset

How to Detect the Fault?

Troubleshooting Steps

When performing a password reset, but no email confirmation is received from the system.

image-20240606-111653.png
  1. Press the “Forgot Password” option again and check your email inbox and your spam folder too.

  2. Verify that your email address is not blacklisted. Ask another user in the organization to perform the operation as follows: https://galooli.atlassian.net/wiki/spaces/KP/pages/2581987333/Access+Security#Blacklist-Removal

  3. It is recommended that you try to recover the password again if the email address is not on the blacklist.

  4. In the event that none of these steps are successful, open a ticket to the Galooli support with the user's information. The ticket should contain all the details and actions taken so far.

The Power Consumption Tool Did Not Display Some Units

How to Detect the Fault?

Troubleshooting Steps

The Power Consumption tool does not display a unit when attempting to locate it.

image-20240609-075036.png

There are certain conditions that must be met by the user and the unit in order to see the unit in the Power Consumption tool.

The following link provides a complete list of conditions.

https://galooli.atlassian.net/wiki/spaces/KP/pages/2919792687/Power+Consumption#Unit-Display-Conditions


Email Event Notifications Not Received

How to Detect the Fault?

Troubleshooting Steps

Despite the fact that the event occurred, no email notification is received.

image-20240620-115815.png
  1. Verify that an email is not received only within this particular unit or throughout the entire organization.

  2. Ensure that your email address is not blacklisted through the organization manager. How To Remove Email Addresses From The Blacklist?

  3. You should make sure that the setting is configured so that when this specific event occurs, an email should be sent (Events) and, make sure that your email is properly documented (Overview).

  4. Create and test different event on the same problematic unit in order to determine whether there is an issue with the event or with the unit itself. "Location Request By User" is the recommended event.
    Events

    image-20240620-124941.png


    Once you have created the event and updated your email address, enter the Panorama application, select the unit from the organization tree, click on the Live view, and then click on “Request Update”.

image-20240620-125113.png
  1. In the event that you have not received an email after trying all possible methods, please submit a ticket to the Galooli support team. The details of all tests as well as the unit must be included in the ticket. Galooli Support

Unable To Upgrade a Unit Via Serial Connection

How to Detect the Fault?

Troubleshooting Steps

In the power center/configuration center the communication lost

IMAGE - TBA

  1. Check if the RS485 convertor usb connected properly.

  2. מומלץ להשתמש רק בקונוורטור של גלולי

  3. Close and open the platform. תנסה שוב

  4. לנסות לעדכן לגרסה קודמת

  5. אם גרסה קודמת עובדת אז הבעיה בגרסה ויש לפתוח טיקט

  6. אם הבעיה לא גרסה אז יש להחליף לקונוורטור אחר

  7. אם הבעיה ממשיכה יש לפתוח טיקט