This feature is available only to organizations with a Platinum license.

My X-Ray provides an environment for managing configurations, defining valid ranges for each configuration and setting the required values for different devices.

All operations are carried out by creating and managing X-Ray tables that contain information about the device parameters, the valid ranges selected by the user, and, of course, the set values that binds the X-Ray item to a specific OID, stores and applies the appropriate parameter types and factors, and applies them accordingly.

image-20240129-111932.png

X-Ray Existing Tables Section

This section includes the X-Ray tables prepared by the user and all X-Ray system tables prepared by Galooli.

The table specifies:

  • Type (system/user-costumed tables) indicated by icons.
    System tables:

    • Appear as default for all organizations.

    • Will appear first in the table (before all user-costumed tables).

    • Will appear with a "System" icon (Gear).

    • Cannot be edited or removed.

  • Name

  • Device

  • Description

image-20240129-112101.png

X-Ray Table Configuration Section

Upon selecting one of the existing X-Ray tables, the following data will appear on the right side of the screen:

  • Name

  • Description

  • X-Ray Items (Parameters)

  • Valid Range

  • Set Value

image-20240129-112204.png

X-Ray Table Creation/Editing/Removal

Creation/Editing

  1. Click on "Add" to create a new table, a dropdown will open with the options of the table types, according to the possible devices. Alternatively, you may edit an existing table by clicking on it.

  2. From the right side of the screen add the “Name” and “Description” for your table.

  3. There will be a list of all fields associated with the selected device. Identify the relevant fields.

  4. When you double-click on the relevant field, a popup will appear where you can enter the valid range and set value.

image-20240129-112522.png
  • Textual fields popup:

    image-20240128-133652.png
  • Numeric fields popup:

    image-20240128-133732.png
  1. Save the configuration.

Characteristics of “Set” values:

  • The 'Set' value must be in the 'Valid Range', or equals to the 'Valid Range' in case of textual fields.

  • Set value can be empty even if the “Valid Range” has a value (this will indicate the field will not be part of the X-Ray Set).

  • 'Set Value' will be disabled if the field is not settable (for example, LIB Serial Number)

Removal

  1. Select an existing user-costumed type table (not a system type table).

  2. Click on “Remove”

    image-20240129-112921.png

    image-20240129-112945.png