X-Ray Management provides an environment for managing configurations, defining valid ranges for each configuration and setting the required values for device.

X-Ray Management serves the following purposes:

  • Define and update the valid configurations for each device, which will be compared to the actual readings in the X-Ray KPIs menu.

  • Set (write) the valid configurations that the user has defined. For each device, the user will define the specific value for each X-Ray item (can be uploaded from Excel or edited through the configuration table). It will bind the X-Ray item to a specific OID, store and apply the suitable parameter type and factor.

Image - TBA

Existing Calibrations Section

A table with all the calibrations prepared by the user and all system tables prepared by Galooli.

The table specifies:

  • Type (system/user-costumed tables) indicated by icons.
    System tables:

    • Appear as default for all organizations.

    • Will appear first in the table (before all user-costumed tables).

    • Will appear with a "System" icon (Gear).

    • Cannot be edited or removed.

  • Name

  • Device

  • Description

Image - TBA

Calibration Configuration Section

By selecting one of the rows in the calibrations in the existing calibrations section, the X-Ray table will appear on the right side of the screen, specifying:

  • Name

  • Description

  • X-Ray Items (Parameters)

  • Valid Range

  • Set Value

Image - TBA

Calibration Creation/Editing/Removal

Creation/Editing

  1. Click on "Add" to create a new table, a dropdown will open with the options of the table types, according to the possible devices. Alternatively, you may edit an existing table by clicking on it.

  2. From the right side of the screen add the “Name” and “Description” for your calibration table.

  3. There will be a list of all fields associated with the selected device. Identify the relevant fields.

  4. When you double-click on the relevant field, a popup will appear where you can enter the valid range and set value.

    Image - TBA

  • Textual fields popup:

    image-20240128-133652.png
  • Numeric fields popup:

    image-20240128-133732.png
  1. Save the configuration.

Removal

  1. Select an existing user-costumed type table (not a system type table).

  2. Click on “Remove”

    Image - Remove