Skip to end of banner
Go to start of banner

Analog AC Current Sensor Troubleshooting

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 14 Current »


AWL Troubleshooting

How to Detect the Fault?

Fault Description

Troubleshooting Steps





There is no light coming from the AWL





The AWL is not receiving power

The sections should be progressed according to the solution

  1. Make sure the power switch of the AWL is turned on

  2. During the light hours, cover the AWL light sensor to make the AWL turn on, and check if the AWL works properly.

  3. Check the AWL in the evening or at night

  4. The tower bulb or the entire AWL system needs to be replaced

Power Center Communication Troubleshooting

How to Detect the Fault?

Fault Description

Troubleshooting Steps



There is no indication on the Power Center that the AWL is functioning



Although AWL is working properly, there is no indication of that in the Power Center

The sections should be progressed according to the solution

  1. Make sure the AWL works with AC current (click here for AWL that work with DC current)

  2. Make sure the cable connection between Elara/Tray/Metal box and AWL is proper. Ensure that the cables are connected properly and that they are not torn

  3. The connections should be connected as described in the wiring diagram provided by Galooli