Field Name

Field Description

Generator X Total Manual Mode Hours

The total hours the generator spent in manual mode over the period selected. Here is how the calculation is performed:

  • There must be a minimum of 15 minutes between the last broadcast and the current broadcast, unless it is a SWAN gateway, in which case it must be a maximum of 75 minutes.

  • Generator_X.Running = True AND Generator_X.Working Mode = Manual

Generator X Initial Engine Hours

The first/ last record of the engine hour value for the selected time range. 
Based on the field Site_Global.DGX_Engine_Hours.

Data aggregation should be performed on the fields on a daily basis.

Generator X Final Engine Hours

Generator X Total Engine Hours

The total hours the engine was running in the selected time range. Based on the field Site_Global.DGX_Engine_Hours.

Data aggregation should be performed on the fields on a daily basis

Generator X Overall [Liter/H]

The fuel rate of the generator in terms of a liter per hour. The fuel rate is calculated according to the fuel consumed (including drops) and the engine hours.

Generator X Overall Fuel [Liter]

The total amount of fuel consumed (including fuel drops) in the selected time range.

Generator X Fuel Sensor Operational Consumption [Liter/H]

The fuel rate of the generator in terms of a liter per hour. The fuel rate is calculated according to the fuel consumed (not including drops) and the engine hours.

Generator X Operational Fuel [Liter]

The total amount of fuel consumed (not including fuel drops) in the selected time range.

Generator X Fuel Drops

Number of fuel drops in the selected time range.

(warning) In order to collect this data, a fuel drop event must be created - Fuel Events*

Generator X Total Fuel Drop [Liter]

The total amount of fuel that was lost as a result of fuel drops.

(warning) In order to collect this data, a fuel drop event must be created - Fuel Events*

Generator X Refuels

Number of refuels in the selected time range.

Generator X Total Refueled [Liter]

The total amount of fuel that was refueled in the selected time range.

Generator X Ignition Count

Number of generator ignitions during the selected time range.

Generator X Initial Fuel [Liter]

The fuel level of the generator in the first/last record in the selected time range.

Generator X Final Fuel [Liter]

Generator X Minimum Fuel Level [Liter]

The minimum fuel level value of the generator in the selected time range.

Generator X Frequency Max [Hz]

The minimum and a maximum frequency of the generator in the selected time range.

Generator X Frequency Min [Hz]

Generator X Battery Voltage Max [V]

The minimum and a maximum voltage of the generator's battery in the selected time range.

Generator X Battery Voltage Min [V]

Generator X Oil Pressure Max, Min, Avg* [kPa]

The minimum, maximum and average oil pressure of the generator in the selected time range.

Generator X Total Flow Meter Fuel [Volume]

Fuel consumption from a dedicated sensor (Flow Meter) on a daily basis.

Generator X Average Flow Rate [Volume\Hour]

The daily average of fuel that passed through the sensor (Flow Meter per hour.



Generator X

Load based Fuel

- Galooli Operational Consumption [

Km

Liter/

Liter

H]

When the 'standard' data for the fuel consumption rate 

Whenever there's an illogical result in the sensor fuel consumption reading (Generator X Fuel Sensor Operational

consumption

Consumption [Liter/

Hour

H])

exceeds the logical range

, the

new field calculates the estimated fuel consumption by estimating the fuel consumption based on the

field will show an assessment of the fuel consumption based on the following:

  1. Final and initial fuel levels considering drops and refuels.

  2. Fuel consumption patterns of the generator.

  3. Estimated consumption based on generator's load and the KVA

.
Estimated Load based consumption = A * Generator (1\2) Load Power Average [kWh] / (0.8 * Generator.generator1\2.KVA) + BWhen A and B are coefficients that change according to the generator's KVA.

Generator KVA must be configured below the additional info.

https://galooli.atlassian.net/wiki/spaces/KP/pages/2830041108/Information#Additional-Information

Generator X Load Based

Fuel

Consumption

(

[Liter/H

)Whenever there's an illogical result in the system fuel consumption parameters (Generator 1 Operational Consumption [Liter/H]), the CPH field will show an estimated consumption

]

Provide the estimated fuel consumption tailored to the generator's specific KVA, calculated based on the generator's load

and the KVA
  • Use the value of the parameter "Generator X Operational Consumption [Liter/H]" if it doesn't out of the valid range (Based on internal valid ranges CPH table)

  • If "Generator X Operational Consumption [Liter/H]" values are out of this range, than use the calculation Y=CPH Result, X = Generator Load [%]:
    Generator Load

    .

    Logic:

    Generator load [%] = (Generator1/2 Load Power - Avg [kW])/(0.8 * Additional info → Generator.Generator1/2.KVA)

    *Zeros are ignored in the calculation of averaged fields