The latest version of the Galooli solution incorporates features that reflect our open dialogue with our customers and Galooli's desire to facilitate and improve the system's use. The purpose of this article is to provide information about the main features of this version.
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
General Updates
Updated Articles
New Academy Lesson - https://galooli.atlassian.net/wiki/x/AQAe4Q
New Ultragate Tray Cabinet - https://galooli.atlassian.net/wiki/x/mYDssQ
Sparta Lead Acid Gateway New Version (4.18) - https://galooli.atlassian.net/l/cp/Ac16hCof
Sparta Lithium-ion Gateway New Version (2.15) - https://galooli.atlassian.net/l/cp/dAeBV14J
New Enersys Rectifier Model Support (SFX_MCU2) - https://galooli.atlassian.net/l/cp/MsQR9iV8
New Hardware Support and Integration
Dahua DH-IPC Network Camera - New integration
CBEIL PTZ Network Camera - New network camera support and new integration
Logout Mid-Session New Error Message
A new error message has been added to the system to notify the user when they are disconnected due to simultaneous connections from two stations/browsers using the same user account.
Pro Application
New Summary Fields & Updates
A new summary fields have been added to the Galooli reports system:
“Grid Outage Count” - This field will calculate the number of occurrences (relative to the report period and aggregation) where the “Site_Global.Alarm Galooli Grid Fail” field changed from 'No' to 'Yes'.
Read More - https://galooli.atlassian.net/wiki/x/BQCQqg
“Rectifier 1 - Solar Module X Output Power Max [kW]”
“Rectifier 1 - Solar Module X Output Power Avg [kW]”
“Rectifier 1 - Solar Module X V Max/Avg” renamed to "Rectifier 1 - Solar Module X Input Voltage Max/Avg"
“Rectifier 1 - Solar Module X I Max/Avg” - renamed to "Rectifier 1 - Solar Module X Output Current Max/Avg"
Read More - Rectifiers Fields
“Generator X Ignition Count” Update Logic:
Add an ignition to the counter if Site Global Generator X Running was false in the previous record, and true in the current record (state changed from false to true)
Ignore records where Site Global Generator X Running is false AND Generator X Disconnected is true.
Lithium Ion Battery Field Name Updates
Changes to Lithium Ion Batteries (LIB) fields names across the Galooli system (My X-Ray | Pro | My Units)
The field “Module #X” has been renamed to “Module Version”.
The field “SerialNumber” has been renamed to “Serial Number”.
The “LIB” prefix has been removed from the field names displayed in the X-Ray table.
Galooli Automations - Control Commands Permissions
A new permissions verification mechanism has been implemented for the Automations tool.
If an automation is triggered by a user lacking the Control Commands permission and includes a command from the designated command list, the automation will fail execution.
During a script Verify process, the code will "break," and an error message will be displayed to the user.
Read More - https://galooli.atlassian.net/l/cp/11TasXKx
“Status” Field Changes
We have removed several options from the filtering details of the field “Status”:
Alert
Unknown
Upgrade Process
NOC Application
Shelter Alarms Changes
NOC environment alarms have undergone several changes, including:
Updated Alarm Names: Renamed alarms to improve clarity and alignment with the system's terminology.
Individual Shelter Alarms: Introduced distinct alarms for each shelter (Shelters 1, 2, 3, and 4) for better specificity and monitoring.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2605350930/NOC+Alarms+List#Environment-Alarms
Manager Application
New Humidity Sensor Support
Starting from the upcoming version, we will offer support for a humidity sensor (for Shelter 1-4).
Configuration:
The sensor configuration can be done in the configuration tab within the unit editing window (My Units).
The humidity sensor will appear in the expansion tab for Shelter 1-4 after the unit's next transmission.
Thresholds:
A threshold for a humidity alarm (Non-Urgent level) can be configured under KPI → Environment Section in the unit editing window.
Additionally, a corresponding field has been added to the Organizational KPI, with a default value of 80%.
The Galooli Humidity High Alarm will be triggered if:
Humidity Configured = True
Humidity > KPI
KPI ≠ 0
(not zero).
Audit Trail - OTA Logs
The logs of over-the-air (OTA) actions are now documented and displayed in the Audit tool. The feature is already available in the Galooli Solution.
Read More - Audit
IOs Invert State & Panic Display
The checkboxes “Invert State” and “Panic” will only be displayed to the user when the IO is of type Digital and configured as an Input (Digital 1–50). In all other cases, these checkboxes will not be shown.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/2830401910/IO+s#IO%E2%80%99s-Creation
X-Ray KPIs & My X-Ray Filter Default State
The default filtering configuration for the X-Ray tables and the X-Ray KPIs component under the Unit Configuration in My Units has been updated. The new default will display only rows with values. This filter can be toggled on and off using the following button.
Read More - https://galooli.atlassian.net/wiki/spaces/KP/pages/3094183938/X-Ray+KPIs#X-Ray-Parameters / https://galooli.atlassian.net/wiki/spaces/KP/pages/2915762177/My+X-Ray#X-Ray-Table-Configuration-Section
X-Ray KPIs | My X-Ray |
---|---|
Sub-Menu Name Change
The sub-menu/tab previously named "Installation Setups" under the Configuration Menu has been renamed to "Setups."
My Calibrations - Removed Calibration Types
Two calibration types have been removed from the Calibration Type menu in My Calibrations within the Manager application:
Thermistor_NTC
Polynomial Calibration
Shelters Support
We have removed support for configuring more than four Shelters per unit.