The AC Meter is a three-phase electrical isolation transducer.

...

Features

...

  • Three-phase energy analyzer

  • RS485 communication port

  • Easy installation

  • Support high current CT rings

Technical Specification

Power Supply

Self powered

Rated Voltage

400V LL AC

Rated Current

65A

Rated voltage L-N

113V to 265 V LN

Rated voltage L-L

196V to 460 V LL 

...

Technical Specifications

View file
nameEM24 DIN.pdf

 EM24 Direct Pinout Diagram

Pin number

Description

1

PHASE 1 Voltage (input)

3

PHASE 1 Voltage (output)

4

PHASE 2 Voltage (input)

6

PHASE 2 Voltage (output)

7

PHASE 3 Voltage (input)

9

PHASE 3 Voltage (output)

11

N

41

RS485 B (Labeled A-)

42

RS458 A (Labeled B+)

43

GND

...

 

EM24 CT Ring Pinout Diagram

Pin number

Description

1

PHASE 1 Voltage (input)

3

PHASE 2 Voltage (input)

5

PHASE 3 Voltage (input)

7

N

8

CL1+

9

CL1-

10

CL2+

11

CL2-

12

CL3+

13

CL3-

55

0V

57

220V

41

RS485 B (Labeled A-)

42

RS458 A (Labeled B+)

43

GND

...

Recommended Configuration for Galooli Gateways

  • Recommended Galooli gateways:

Elara

Corona

  • Power Center recommended configuration