Skip to end of banner
Go to start of banner

CE-AD91 Data Logger (device extension)

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Next »

Untitled.png

The CE-AD91 Data Logger extension enables the expansion different gateways like the Elara, Techbase, and Axiomtek.

With the CE-AD91 Data Logger connected to the gateway tray/metal box, a greater quantity of analog and digital sensors may be connected to the gateway.

Item ID

  • Manufacturer's website - SSET

  • Manufacturer PN. - CE-AD91-34MN3-0.5

  • Manufacturer Spec -

  • Galooli PN. - 200-CorEX2001-SSET

Hardware Specifications

Power Supply

  • 9 - 30 V

Input Signal

  • Measuring range: 14 channel voltage 0-15V inputs (Rin>100KΩ)

  • Overload: 2 times in 1 second without damage; 1.2 times can be measured correctly.

  • A/D speed : 800mS

Output Signal

  • Output: 2 channel open collector

  • Max. continuous working current: 200mA

  • Overcurrent protection: 300mA

  • Max working voltage: 40V

Communication

  • Output interface: RS485,two wire,±15KV ESD protection

  • Protocol: MODBUS-RTU

  • Baud rate: 19.2K(default), 9600, 4800, 2400, 1200

  • Address: 01H~FFH, 01 as default

  • Parity check: odd check, even check, no check (default)

Surge Impact Immunity

  • Input terminal: ±2KV,Level 4

  • Output terminal: ±1KV,Level 3

  • Power supply terminal: ±2KV,Level 4

Other Parameters

  • Accuracy: 0.5%,24 bits

  • Linearity: 120%

  • Isolation voltage: 2500V DC, double isolation, the power supply is not isolated with output.

  • Rated consumption: <0.5W

  • Temperature drift: 200ppm/℃

  • Operating temperature: -20℃~60℃

  • Storage temperature: -40℃~85℃

  • Humidity: 5%~95% no dew

  • Dimensions: 122mm * 70mm * 43mm

  • Mounting: 35mm din rail mounting

Pinout

Pin#

Definitions

Description

1

VCC

Positive of power supply

2

GND

Negative of power supply

3

DATA+

Positive of RS485

4

DATA-

Negative of RS485

5

AGND

GND for 1st channel and 2ndchannel open

6

OUT1

1st channel open collector output

7

OUT2

2nd channel open collector output

8

UIN11

11th channel voltage input

9

UIN12

12th channel voltage input

10

UIN13

13th channel voltage input

11

UIN14

14th channel voltage input

12

AGND

GND for 11th~14th channel voltage input

13

UIN10

10th channel voltage input

14

UIN9

9th channel voltage input

15

UIN8

8th channel voltage input

16

UIN7

7th channel voltage input

17

UIN6

6th channel voltage input

18

AGND

GND for 6th~10th channel voltage input

19

UIN5

5th channel voltage input

20

UIN4

4th channel voltage input

21

UIN3

3rd channel voltage input

22

UIN2

2nd channel voltage input

23

UIN1

1st channel voltage input

24

AGND

GND for 1st~5th channel voltage input

image-20240618-085242.png

Status LEDs

TBA

Dimensions

image-20240618-084806.png

  • No labels