Supported Models
LG-ChemCommunication Method
RS485 connectionWiring Diagram
Comm | RJ50 bottom side ports |
A | 4,5 |
GND | 1,10 |
B | 2,3 |
Network configuration
Device Baudrate | 19200 |
---|---|
Device ID | All modules share the same master device ID (usually 0x01). see Galooli configuration tool for module detailes |
Alarms List
Critical | Urgent | Non Urgent | Observation |
---|---|---|---|
"Cell Over Voltage Fault 2" | "Cell Over Voltage Fault 1" | "Cell Over Voltage Warning" | "Cell Over Voltage Alarm" |
"Cell Under Voltage Fault 2" | "Cell Under Voltage Fault 1" | "Cell Under Voltage Warning" | "Cell Under Voltage Alarm" |
"Over Charging Current Fault 2" | "Over Charging Current Fault 1" | "Over Charging Current Warning" | "Over Charging Current Alarm" |
"Over Discharging Current Fault 2" | "Over Discharging Current Fault 1" | "Over Discharging Current Warning" | "Over Discharging Current Alarm" |
"Available charge limit over Fault 2" | "Over Temperature Fault 1" | "Over Temperature Warning" | "Over Temperature Alarm" |
"Available discharge limit over Fault 2" | "Under Temperature Fault 1" | "Under Temperature Warning" | "Under Temperature Alarm" |
"Over Temperature Fault 2" | "Cell Voltage Difference Fault 1" | "Cell Voltage Difference Warning" | "Over SOC Alarm" |
"Under Temperature Fault 2" | "Module Temp Difference Fault 1" | "Available charge limit over Warning" | "Under SOC Alarm" |
"Internal Communication Fault 2" | "Available charge limit over Fault 1" | "Available discharge limit over Warning" | "Module Temp Difference Alarm" |
"Pack Under Voltage Fault2" | "Available discharge limit over Fault 1" | "Under SOC Warning" | "Available charge limit over Alarm" |
"BMS HW Fault 2" | "Internal Communication Fault 1" | "Over SOC Warning" | "Available discharge limit over Alarm" |
"External Communication Fault 1" | "Under SOH Alarm" |