The latest version update of the Galooli Gateways includes features that reflect an open dialogue with our customers and Galooli’s desire to facilitate and improve hardware usage. This article contains information about the main features.

  • Inverter/Charger Device Group
    The "Inverter-PV", and "Inverter-Battery" groups in the Elara device configuration process have been merged into a single group called “Inverter-Charger ”. כחלק מהתמיכה שאנחנו נותים

  • New parameters for the various devices

Query Retries

This parameter determines the number of times to remain in each register or object before concluding that communication is not normal. In general, the default value is 2 and this is the recommended value, although there may be occasions when we need to change it.

Connecting Timeout (Modbus over TCP & SNMP ETH devices)

This parameter determines whether or not the communication status should be checked prior to initiating the information request, and for how long. The default value is 0 and this is the official recommendation.

The two parameters are designed to ensure more stable communication, especially with solar inverters of different types.

  •  Elara Ethernet Version
    The Elara gateway's Ethernet module will be updated to “Gal-B”.

  • Parity Bit Configuration

As of this version, Galooli supports different "Parity Bit" options in addition to the "None" default option. The options are: “Even” and “Odd”, and that in order to facilitate new integrations with devices of varying versions. New options have been added to the Elara device configuration menu and the "Direct-Comm" menu.

  • Updated Device Names

Old Name

New Name

VICTRON_PV_MPPT

VICTRON_SMART_SOLAR_MPPT

SMA_SUNNY_TRIPOWER

SMA_PV_SUNNY_TRIPOWER_BLUE

SMA_SUNNY_ISLAND

SMA_BATTERY_SUNNY_ISLAND_YELLOW

SMA_PV_SUNNY_BOY_RED (new device)

SMA_SUNNY_TRIPOWER_SMART_ENERGY (new device)

  • RPT Power New LIB Support
    The Power Center now supports new RPT-NCM48235 LIBs. New LIBs are manufactured by the “RPT Power” company.

  • Forlong New AC Meter Support
    The Power Center now supports a new “Forlong-DRT-301C-II” AC Meter. New AC Meter is manufactured by the “Forlong” company.

  • Victron Cerbo-GX New Product Support
    Power Center now supports a new product from Victron. A Victron Cerbo-GX product allows you to monitor battery charge, power consumption, and power harvest from PV, generator, and mains, or to measure tank levels and temperatures.

  • Acrel New DC Meter Support
    The Power Center now supports a new “Acrel-PZ72L” DC Meter. New DC Meter is manufactured by the “Acrel” company.