  • Supported Models
    LG-Chem

  • Communication Method
    RS485 connection

  • Wiring Diagram

Comm

RJ50 bottom side ports

A

4,5

GND

1,10

B

2,3

  • Network configuration

Device Baudrate

19200

Device ID

All modules share the same master device ID (usually 0x01). see Galooli configuration tool for module detailes

Alarms List

Critical

Urgent

Non Urgent

Observation

"Cell Over Voltage Fault 2"

"Cell Over Voltage Fault 1"

"Cell Over Voltage Warning"

"Cell Over Voltage Alarm"

"Cell Under Voltage Fault 2"

"Cell Under Voltage Fault 1"

"Cell Under Voltage Warning"

"Cell Under Voltage Alarm"

"Over Charging Current Fault 2"

"Over Charging Current Fault 1"

"Over Charging Current Warning"

"Over Charging Current Alarm"

"Over Discharging Current Fault 2"

"Over Discharging Current Fault 1"

"Over Discharging Current Warning"

"Over Discharging Current Alarm"

"Available charge limit over Fault 2"

"Over Temperature Fault 1"

"Over Temperature Warning"

"Over Temperature Alarm"

"Available discharge limit over Fault 2"

"Under Temperature Fault 1"

"Under Temperature Warning"

"Under Temperature Alarm"

"Over Temperature Fault 2"

"Cell Voltage Difference Fault 1"

"Cell Voltage Difference Warning"

"Over SOC Alarm"

"Under Temperature Fault 2"

"Module Temp Difference Fault 1"

"Available charge limit over Warning"

"Under SOC Alarm"

"Internal Communication Fault 2"

"Available charge limit over Fault 1"

"Available discharge limit over Warning"

"Module Temp Difference Alarm"

"Pack Under Voltage Fault2"

"Available discharge limit over Fault 1"

"Under SOC Warning"

"Available charge limit over Alarm"

"BMS HW Fault 2"

"Internal Communication Fault 1"

"Over SOC Warning"

"Available discharge limit over Alarm"

"External Communication Fault 1"

"Under SOH Alarm"

Supported Parameters

Power Center Parameters

System Parameters

Remarks

Battery_SOC_Percentage

Smart_Battery_X.SOC

Battery_SOH

Smart_Battery_X.SOH

 

Voltage

Smart_Battery_X.Voltage [V]

 

Current

Smart_Battery_X.Current [A]

 

Cell_Voltage_Min

Smart_Battery_X.Cell_Voltage_Min [V]

 

Cell_Voltage_Max

Smart_Battery_X.Cell_Voltage_Max [V]

 

Temperature_1-2

 

 

Smart_Battery_X.Temperature_1-3 [Celsius]

Temperature 1 - cell temperature

Temperature 2 - cell temperature

Since lithium batteries are prone to catching fire and exploding at high temperatures, there are two temperature meters for the same purpose.

Battery_Cycles

Smart_Battery_X.Cycles

 