USR-IO (Device Extension - Supported Product)
The USR-IO series is a flexible industrial I/O solution that functions as both a data logger and an extension module, offering reliable data acquisition and remote control capabilities via Modbus RTU over RS485, with configurable analog and digital I/O combinations to suit diverse integration scenarios.
Supported Model
USR_io0080-8do
USR_io0404_4ao_4ai_voltage
USR_io0440_4do_4ai_current
USR_io4040_4do_4di
USR_io8000_8di
Features
Flexible I/O Configuration
Modbus RTU Protocol Support
Data Logger Functionality
Analog Input & Output Support
Extension Module Capability
Status Indicators
Industrial Design
Robust Electrical Protection
Factory Reset Function
12–24V DC Power Supply
Hardware Specifications (USR-IO0404)
Items | Description | |
|---|---|---|
Interface | RS485 | Default: 9600, NONE, 8, 1 |
Options for band rate: 4800, 9600, 115200, 230400 | ||
Parity bit: NONE, EVEN, ODD | ||
Data bits: 8 | ||
Stop bit(s): 1, 2 | ||
Physical Specification | Dimensions | 79.6*58*110(mm) |
Installation | DIN rail mounting & Panel mounting | |
Status LEDs
| POW | Steady on: Power supply is normal Off: No power supply or abnormal power supply |
WORK | Power is on, and the device is ready. System is booted up and running | |
DO | Steady on: The channel output is activated | |
DI | Steady on: The channel is activated input signal | |
Power | Power 2-pin socket | DC: 12-24V |
Protection | EMC Protection | Level 3, IEC 61000 |
Watchdog | Hardware & Software watchdog | |
Flame retardant rating | V0, burning stops within 10 seconds on a vertical part allowing for drops of plastic that are not inflames. | |
Temperature | Operation temperature | -25℃ ~ +75℃ |
Storage temperature | -40℃ ~ +105℃ | |
Humidity | Operation Humidity | 5%~95% (non-condensing) |
I/O | DI | Digital opto-isolated input (0 -2 V detected as logic low,9 -36 V detected as logic high) Not supported in USR-IO0404 Model |
AI | Analog input 4-20mA | |
DO | Relays, the endurance is 100,000 operations. DC contacts rating @R (at resistive load) 3A / 30V DC. AC contacts rating @R (at resistive load) 3A / 250V AC, NO Not supported in USR-IO0404 Model | |
AO | Analog output: voltage output: 0-10V, current output: 4-20mA | |
Modbus | Slave address | Range: 1~255 Default: 1 |
Pinout (USR-IO0404)
AO-Analog Output
AI-Analog Input
Wiring
Fan Wiring
Power Center Configuration
ID Configuration
Connect the RS485 converter to the PC/laptop and connect the other ends of the wires to the Data Logger.
Open Power Center > Open the “Active Device” drop-down menu, and select the “Power Device”
Click on “Services Center” > “DataLogger USR-IOxx” > Set the “Communication Baudrate” to 9600 > Check the “ID Scan Mode” – to find the current ID default of the device.
Please note! If the current device ID is set according to your wiring diagram, then no additional action is needed, and move on to the next stage.
Click “Next”
In “Device ID” – set the ID device according to your wiring diagram, then click the “Set New Configuration” button.
Please note! Make sure that the “Communication Baudrate” stays on 9600.
10. Click “Yes” when a window will pop up.
12. Once the Power Center detects the device, values will appear in the “Reading Results” section.