QFY Fuel Meter Flow (Supported Product)
QFY Fuel Meter Flow provides accurate and reliable fuel flow measurement, ensuring optimal performance and efficiency in various applications.
Features
Feature | |
|---|---|
Accuracy | ±0.1 %FS @ 20–25 °C |
Stability | ±0.15 %FS/year under reference conditions |
Outputs | 4–20 mA (2-wire) or 0–10 V / 0–5 V (3-wire) + RS485 |
Digital protocol | RS485 half-duplex, Modbus RTU |
Compensation | Pressure & temperature compensated (0–50 °C) |
Housing | AISI 316L, welded diaphragm |
Protection | IP68, submersible |
Operation | Continuous duty, long-term immersion |
Supported Models & Communication Method
Model | Communication Method |
HT20-G10-TX | RS485 (Modbus) |
Technical Specifications
Flow range | 0.5~16m³/h |
Working pressure | ≤1.0Mpa |
Accuracy level | Level 1.5 |
Medium | Natural gas, compressed air, carbon dioxide, nitrogen, propane and other non-corrosive gases |
Single measurement | 0~99999.9 |
Total cumulative amount | 0~9999999.9 |
Working temperature | -20℃~ 60℃ |
Pressure compensation | 0~1.0Mpa(Fully automatic real-time pressure correction) |
Battery power | 3 y e a r s ( 3 . 6 V / ER 1 4 50 5 / S i z e 5 / 2 p i e c e s ) |
Measurement unit | Nm³/L |
Real-time flow | Nm³/h / /L/min |
Communication method | ModBus-RTU RS-485/Pulse |
Wiring/Pinout Diagram
Red | V+ | Power supply positive 5~24V+ |
Black | V- | Power supply negative VO |
Green | A | RS485-A |
Yellow | B | RS485-B |
Orange | PLO | Pulse output line |
Note: When using the signal output, it must be connected to the power supply | ||
Physical Installation
Can be found under Chapter 8 in the Manufacturer Data.
Device Configuration
Can be found under Chapter 5 in the Manufacturer Data.
Power Center Configuration
Manufacturer Data