Tray Set
The Galooli Tray Set is a durable indoor mounting solution designed to host a DC-DC converter, a Galooli gateway, and expansion modules. It features terminal block connections for simplified wiring and faster installation.
The tray structure varies depending on the gateway model.
The Tray Set is compatible with standard cabinets and is designed for installation in a 19-inch rack with a 2U height.
Elara Gateway Tray Set
Ultragate Gateway Tray Set
Supported Models
Item Name | Galooli PN | Gateway | Including/Remarks |
|---|---|---|---|
Tray for Ultragate 19'' 2U
| 400-UltraTry2U-5071 |
Ultragate | 400-DcdCUI12V-028- Meanwell Ready for battery installation |
Tray Set for Ultragate 19'' 2U, Incl. DC-DC, SPD
| 400-UltraTry2U-5071-SET | 400-UltraTry2U-5071 400-DcdCUI12V-028- Meanwell 400-EXSPD-507 EX-SPD Ready for battery installation | |
Tray Set for Ultragate 19'' 2U, Incl. DC-DC, SPD, Backup Battery
| 400-UltraTry2UBattery -5071-SET | 400-UltraTry2UBattery -5071 400-DcdCUI12V-028- Meanwell 400-EXSPD-507 EX-SPD Battery Cables | |
Tray for Elara 19'' 2U | 400-ElaraTry2U-5071 | Elara |
|
Tray Set for Elara 19'' 2U, Incl. DC-DC | 400-ElaraTry2USET-507 |
| |
Elara Tray to Ultragate Tray Replacement Kit | 400-ElaratoUltraTry2U-5071 | Elara To Ultragate | If an EX20 is present in the tray, the connection method changes after replacing the KIT. After that, connect all sensors directly to the EX20 instead of the terminal block. Clients are required to order SPD units separately, based on the number of trays needed. |
Tray Set for Axiomtek (Not Supported) | 400-AXITry2U-5071 | Axiomtek | Not Supported |
Tray Set for TechBase 19"" 2U, Incl. DC-DC (Not Supported)
| 400-TehTry2U-5071 | Techbase | Not Supported |
Technical Specification
Size | Elara – Length: 40 cm × Width: 41 cm × Height: 8 cm |
Weight | Elara - 7 kg |
Standards and Certification |
|
Tray Set Parts | Blank Panel |
2 Side Rails | |
Elara Tray Set | |
Ultragate Gateway Tray Set
|
Data Sheets
Cabinet Layouts
Ultragate Tray Set Layout
In telecom sites we have many sensors and panels, therefore, we created this efficient tray, to help manage all the wires, and to be on top of things.
The specification applies to both the Tray Set and the Metal Enclosure Set.
There is dedicated compatibility between the Ultragate gateway and the Tray Set/Metal Enclosure Set.
Main Input Fuse
This is the main fuse and input of electricity for the tray, it can receive from +18VDC to +75VDC, the main fuse need to be connected to the DC to DC power converter.
DC to DC Converter
The converter converts the input voltage (18VDC-75VDC) to +12V, since most of the sensors and devices, including the gateways, are working on +12VDC.
Grounding
Grounding is made to protect the sensitive electrical equipment in the tray, the grounding resistance should not be more than 5Ω.
GND & +12V Terminal
Extension terminal for GND and +12V power.
These are the main power slots for all the consumers in the tray, it is receiving power from the DC to DC converter. Any device in the tray should consume power only from the terminal blocks.
RS485 Terminal
Extension terminal for the gateway RS485 port, to provide a serial connection between the gateway and the other devices and sensors on the site.
The orange terminal is for Port A and the blue wires are for Port B
Gateway Slot
The gateway slot is a place for the gateway on the din rail, with the exact length of the green connectors, dedicated for the gateway.
Gateway Terminal
All the inputs & outputs of the gateway & EX20 are extended to the gray terminal, to have organized & comfortable connections to the devices.
Each input in the gray terminal directly extends the actual input in the gateway or EX20.
Hatch Sensor
The Hatch Sensor exists to indicate if the tray is opened.
As a convention, it always will be connected to the 5th input of the gateway.
Data Logger Slot
The Data Logger extension enables the expansion of the gateway
With the Data Logger connected to the gateway, a greater quantity of analog and digital sensors may be connected to the gateway.
Surge Protection Device (SPD) Slot
SPD is a device designed to protect electrical systems and equipment from voltage surges caused by lightning strikes, power grid fluctuations, or switching operations. It works by diverting excess voltage away from sensitive components. When connected to the Galooli Tray/Metal Box, a 13.5V charging voltage is required.
Backup Battery
For the adjusted Ultragate battery tray – an external 12V lead-acid battery is connected via a battery charger with a built-in SPD (Surge Protection Device) as an integral component of the tray/metal box.
For the battery to charge, the DC/DC must be set to 13.5V.
This should be an integral part of the process, including verification with a voltmeter to ensure the correct voltage is set.
An example of a fully installed tray with the Ultragate gateway (without the battery):
Elara Tray Set Layout
In telecom sites we have many sensors and panels, therefore, we created this efficient tray, to help manage all the wires, and to be on top of things.
Main Input Fuse
This is the main fuse and input of electricity for the tray, it can receive from +18VDC to +75VDC, the main fuse need to be connected to the DC to DC power converter.
DC to DC converter
The converter converts the input voltage (18VDC-75VDC) to +12V, since most of the sensors and devices, including the gateways, are working on +12VDC.
Grounding
Grounding is made to protect the sensitive electrical equipment in the tray, the grounding resistance should not be more than 5Ω.
Wiring Ducts
Wiring ducts are made for cable organization, all the cables from the sensors & devices on the site are designed to go through these wiring ducts.
GND & +12V Terminal
Extension terminal for GND and +12V power.
These are the main power slots for all the consumers in the tray, it is receiving power from the DC to DC converter.
Any device in the tray should consume power only from the terminal blocks.
RS485 Terminal
Extension terminal for the gateway RS485 port, to provide a serial connection between the gateway and the other devices and sensors on the site.
The orange terminal is for Port A and the blue wires are for Port B
Gateway Slot
The gateway slot is a place for the gateway on the din rail, with the exact length of the green connectors, dedicated for the gateway.
EX20-1/2 Slot
The EX20-1/2 (Extension Devices) slot is a place for the EX20 on the din rail, with the exact length of the green connectors, dedicated for the EX20.
Gateway & EX20-1/2 Terminal
All the inputs & outputs of the gateway & EX20 are extended to the gray terminal, to have organized & comfortable connections to the devices.
Each input in the gray terminal directly extends the actual input in the gateway or EX20.
Hatch Sensor
The Hatch Sensor exists to indicate if the tray is opened.
As a convention, it always will be connected to the 5th input of the gateway.
An example of a fully installed tray with the Elara gateway: