Supported Models
CH48150
Manufacturer site - https://en.changhongbatteries.com/
Communication Method
RS485 connection
Wiring Diagram
Pinout | RJ45 side ports |
1 or 8 | RS485 B |
2 or 7 | RS485 A |
Network Configuration
Device Baudrate | 9600 |
---|
For configuring the physical ID when there are one or more batteries connected to one another, the following actions must be taken. As shown in the table, the "ADD" part must be configured according to the number of batteries, on each battery separately.
Supported Parameters
Power Center Parameters | System Parameters | Remarks |
---|---|---|
Current | Smart_Battery_X.Current [A] | |
Voltage | Smart_Battery_X.Voltage [V] | |
Battery_SOC_Percentage | Smart_Battery_X.SOC | |
Battery_SOH | Smart_Battery_X.SOH | |
Battery_Cycles | Smart_Battery_X.Cycles | |
Temperature_1 | Smart_Battery_X.Temperature_X[Celsius] |