The X-Ray Accuracy is part of the Galooli Manager Application, it provides a visual representation of how the organization is performing in relation to its predetermined configurations and thresholds.

The X-Ray Accuracy displays a dashboard that provides data impacted by configurations made in the complementary tool, X-Ray Management.

The accuracy display provide and overview of the validity of the user's settings. The user will be able to choose different X-RAY parameters (e.g., VPMG, float voltage, etc.) and to apply different filters (e.g., battery type, rectifier type, communication node).

X-Ray Accuracy Structure

X-Ray Dashboard Display

Here, you will find a dashboard with various cards that display the validity of settings as well as a settings history that shows the history of settings over time.

  • No. of Sites - The number of sites within the organization

  • Total Sites with Invalid Configurations - Number of sites with invalid configurations

  • Total Invalid Configurations - Total number of invalid configurations that need to be corrected

  • Configuration Pie Charts - Each pie chart represents an a specific X-Ray item that is being monitored by the organization:

    • The green slices indicate the number of sites with the configuration in the correct value

    • The red slice indicates how many sites have an invalid configuration

    • The grey slice indicates how many sites are not supporting the specific configuration, so it is not relevant for them

Clicking on a specific configuration item on the green or red slices will cause all the data on the screen to be changed in accordance with that item.

Re-click the marked pie section to remove the filter.

X-Ray Filtration Tools

There are filter options on the top of the screen that enable the user to focus on sites that have a particular type of device or layout. The user can also change the X-ray items (charts) that appear on the dashboard.

  • Selected Units - A selection of units from the organization tree, excluding the cluster “STOCK”. The default choice will be the entire organization.

  • Advanced Filter - An advanced filtering tool that allows the user to filter the information according to different devices and models

  • +Charts - The tool allows the user to select which configurations to display. The number of pies in the dashboard is directly affected by this filter

Selected Units

Advanced Filter

+Charts

 

 

 

X-Ray Accuracy Report

The purpose of the Accuracy Report is to identify the specific sites with the configuration issues.

In the accuracy report, the data displayed in the dashboard is represented in a table format. As a result, the table's columns include the selected filters and configurations. The table will only display units that are included in the dashboard (and were not filtered out by the filters or pie charts).