Power Center Parameters | System Parameters | Remarks | ||
---|---|---|---|---|
Battery SOC Percentage | Smart_Battery_X.SOC | |||
Battery SOH | Smart_Battery_X.SOH | Battery Rated Capacity | Battery.General.Capacity [AH] | |
Voltage | Smart_Battery_X.Voltage [V] | |||
Current | Smart_Battery_X.Current [A] | |||
Cell Voltage Min | Smart_Battery_X.Cell_Voltage_Max Min [V] | |||
Cell Voltage Max | Smart_Battery_X.Cell_Voltage_Min Max [V] | |||
Temperature 1-3 | Smart_Battery_X.Temperature_1-3 [Celsius] | Temperature 1 - cell temperature Temperature 2 - cell temperature Since lithium batteries are prone to catching fire and exploding at high temperatures, there are two temperature meters for the same purpose. Temperature 3 - FET temperature | ||
Battery Cycles | Smart_Battery_X.Cycles |
...