Omnicomm LLS 30160 fuel sensor measures the real-time fuel level in the fuel tank. Since the fuel level indication is essential, it is crucial to know what type of fuel sensor and what shape of tank you are dealing with.
תמונה
Technical Specifications
Supply voltage: 7-50V
Speed of data transmission: 1200-115200 (adjustable)
Inaccuracy for measuring the level: ±1%
The standard length of probe: 700, 1000, 1500, 2000, 2500, and 3000mm
Discrimination (resolution): 1 - 4095/1 - 1023 (depends on operation mode)
Rated power: Maximum 0.4W
Temperature range (operating): -40°C to +80°C
Data output interface: RS232 and EIA (RS) 485 Insulate
Dust and water splash protection: IP57
...
The PIUSI K200 meter is an oval gear meter suitable for measuring diesel and oil. Its low flow rate count makes it also applicable to measure the fuel consumption in a system.
Features
Low flow rate operation
Consumption monitoring
Small size
Inlet filter
Dosage system
High pressure resistance
Calibration function
Compact design
Technical Specifications
Manufacturer's website -K200 - Electronic flow meter - International
Manufacturer datasheet
View file | ||
---|---|---|
|
View file | ||||
---|---|---|---|---|
|
Code | 000452000 |
---|---|
Description | K200 PULSER |
Fluids | Diesel, Oil |
Flow-rate | l/min - 0,1 - 2,8 |
Pulser | p/l - 1400 |
Pressure | bar - 30 |
Battery included | No. 2 |
Flange | NO |
Inlet Outlet | BSP - 1/4” |
Inlet filter | YES |
Pinout Diagram
Pin# | Color | Name |
---|---|---|
6 | Red | Power |
7 | Orange | Ignition |
9 >> 3 | Pink >> Brown | Connection to first PIUSI flow meter |
10 >> 4 | Grey >> Brown | Connection to second PIUSI flow meter |
12 | Black | Ground |
TBA | White | Positive Power to the PIUSI flow meter |
...