Extremely low power consumption
Small size
Easy installation
Support 4G/3G/2.5G cellular communication
SIM on chip
Full OTA configuration process
OTA firmware upgrade
Epoxy coverage (option)
Configurable LEDs behavior (for better in-battery concealing)
Physical measurements: Voltage, Current, Temperature, Internal resistance
On-Board Movement sensor
On-Board Temperature sensor
On-Board GPS (Internal Antenna)
Galooli Part Number | Description | ||
---|---|---|---|
100-Sparta-EABT | Sparta Tracker (eSIM,2G&4G ) | Sparta - North America/EMEA/Asia (2G/4G) | eSIM,Box,2G/4G |
100-Sparta-EBBT | Sparta Tracker (eSIM,2G&3G ) | Sparta - Central and south America/EMEA/Asia (2G/3G) | eSIM,Box,2G/3G |
100-Sparta-ECBT | Sparta Tracker (eSIM,2G&3G&4GE ) | Sparta - EMEA/Asia (2G/3G/4G) | eSIM,Box,2G/3G/4G(Europe) |
100-Sparta-EDBT | Sparta Tracker (eSIM,2G&3G&4GE ) | Sparta - North America (2G/3G/4G) | eSIM,Box,2G/3G/4G(North Amrica) |
Hardware Specification
General specifications
...
The unit will begin transmitting its location every minute (default setting) to allow for tracking and tracing. Once the unit remains 10 minutes (default setting) with no movement, it returns to In-Cabinet Mode.
...
.
...
Switching Between Modes
It is possible to switch between the different modes when physically connected to the Sparta (Serial Connection) or when connecting wirelessly (OTA - while the unit is connected to the server).
Important Note - You can switch from "In Cabinet" mode to "Maintenance" mode only when the Sparta is connected to the server. The timing depends on the Sparta's configuration.
Maintenance State Timeout
When Sparta gateway is in one of the following modes: "Storage", "In Cabinet", or "Tracking”, and for some reason, switches to "Maintenance" mode, it will automatically return to the previous mode after one hour, with the exception of the following:-
Every communication with the host (serial of remote) will reset the 1-hour timer.
...
If the device is manually set back to maintenance mode (using the power center button), the device will
remain in maintenance forever.Status is set by the unit itself.
Sparta Status Logic
The Sparta mods and the status in the Galooli solution are linked to facilitate the process of creating an alert.
...
Mode | Galooli Solution |
---|---|
Maintenance | Idle |
In Cabinet | Off |
Tracking | On, Stop, Moving Like all other systems, depends on the speed |
Users can generate events in the system and link the mode to the status.
...
Click the "Write Configuration" button and after the process is complete, click the "Reset" button.
...
Restore the Sparta's status to In Cabinet.
Lead Acid Battery Compliance For Sparta
...
Northstar | Enersys | Fiamm | Sacred Sun |
NSB (150-210)FT | PowerSafe SBS (100-190)F | 12 FIT 101 | FTA12-100 |
| PowerSafe V-FT (100-190) | 12 FIT 100/23 | FTA12-150 |
|
| 12 FIT 150 | FTA12-200 |
|
| 12 FIT 180 |
|
|
| 12 FIT 201 |
|
|
| 12 FHT 101 |
|
|
| 12c FHT 181 |
|
|
| 12 FHC 95 |
|
|
| 12 FHC 175 |
|
|
| 12 FLB 700 |
|
...
|
...
Child pages (Children Display) |
---|
...