Extremely low power consumption
Small size
Easy installation
Support 4G/3G/2.5G cellular communication
SIM on chip
Full OTA configuration process
OTA firmware upgrade
Epoxy coverage (option)
Configurable LEDs behavior (for better in-battery concealing)
Physical measurements: Voltage, Current, Temperature, Internal resistance
On-Board Movement sensor
On-Board Temperature sensor
On-Board GPS (Internal Antenna)
Galooli Part Number | Description | ||
---|---|---|---|
100-Sparta-EABT | Sparta Tracker (eSIM,2G&4G ) | Sparta - North America/EMEA/Asia (2G/4G) | eSIM,Box,2G/4G |
100-Sparta-EBBT | Sparta Tracker (eSIM,2G&3G ) | Sparta - Central and south America/EMEA/Asia (2G/3G) | eSIM,Box,2G/3G |
100-Sparta-ECBT | Sparta Tracker (eSIM,2G&3G&4GE ) | Sparta - EMEA/Asia (2G/3G/4G) | eSIM,Box,2G/3G/4G(Europe) |
100-Sparta-EDBT | Sparta Tracker (eSIM,2G&3G&4GE ) | Sparta - North America (2G/3G/4G) | eSIM,Box,2G/3G/4G(North Amrica) |
Hardware Specification
General specifications
Power Supply | 6 - 16 V |
---|---|
Power Consumption | Storage mode ~25uA |
In Cabinet mode ~25uA | |
Daily report mode (MODEM Only) ~35mA | |
Tracking mode (MODEM+GPS) ~50mA | |
GSM/GPRS | Internal Antenna |
LTE Cat M1/Cat NB1/EGPRS | |
GNSS | Antenna type - Internal |
GNSS Systems 99 acquisition channels Sensitivity -167 dBm | |
Time To First Fix (90% @ -130 dBm) - Cold Start: ‹ 35 s | |
Serial Communication | RS485 |
Memory logger | 10000 messages (Aprox.) |
Storage Temperature | -40 - 85 Celsius |
Working Temperature | -20 - 70 Celsius |
Max. Relative humidity | 90% |
Weight | 34 g (Aprox.) |
Size | 41x86 mm |
Movement detection
Number of Axis | 3 |
---|---|
Full scale | +-2g |
Sampling rate | 50Hz |
Movement detection threshold | 0.25g |
Voltage Measurement
Max voltage | 19v |
---|---|
Resolution | 0.01v |
Accuracy | 0.05v |
Temperature sensor
Sensor type | NTC |
---|---|
Range | [5,50] Celsius |
Resolution | 0.01 Celsius |
Accuracy | 1 Celsius |
Pinout
...
Power
Pin # | Name |
---|---|
1 | V+ |
2 | V+ (not in use) |
3 | V- (not in use) |
4 | V- |
RS485
Pin # | Name |
---|---|
1 | RS485-A |
2 | RS485-B |
3 | GND |
Status LEDs
The LEDs status depends on the type of modem:
...
The unit will begin transmitting its location every minute (default setting) to allow for tracking and tracing. Once the unit remains 10 minutes (default setting) with no movement, it returns to In-Cabinet Mode.
...
...
Switching Between Modes
It is possible to switch between the different modes when physically connected to the Sparta (Serial Connection) or when connecting wirelessly (OTA - while the unit is connected to the server).
Important Note - You can switch from "In Cabinet" mode to "Maintenance" mode only when the Sparta is connected to the server. The timing depends on the Sparta's configuration.
Maintenance State Timeout
When Sparta gateway is in one of the following modes: "Storage", "In Cabinet", or "Tracking”, and for some reason, switches to "Maintenance" mode, it will automatically return to the previous mode after one hour, with the exception of the following:-
Every communication with the host (serial of remote) will reset the 1-hour timer.
...
If the device is manually set back to maintenance mode (using the power center button), the device will
remain in maintenance forever.Status is set by the unit itself.
Sparta Status Logic
The Sparta mods and the status in ZonMax the Galooli solution are linked to facilitate the process of creating an alert.
|
---|
Mode |
---|
Galooli Solution | |
---|---|
Maintenance | Idle |
In Cabinet | Off |
Tracking | On, Stop, Moving Like all other systems, depends on the speed |
Users can generate events in the system and link the mode to the status.
...
It may be necessary to manually configure the Sparta GPS location if there is no cellular GPS reception in a particular location.
Please follow the next steps in order to set the Sparta location manually:
Connect the computer to the Sparta gateway.
Open the Power Center (if the Power Cent was already open, close it, and re-open it).
Open the “Active Device” drop-down menu and select “Power Device”.
Open the “Connect Via” drop-down menu and select the “OTASerial” connection.
...
Provide the relevant login parameters and your Sparta ID.
To set the location manually the Sparta should be in “Maintenance” mode. In order to switch to this mode navigate to the "Sparta" tab and click on “Maintenance Mode”. Please approve the pop-up.
...
Click the "Write Configuration" button and after the process is complete, click the "Reset" button.
...
Restore the Sparta's status to In Cabinet.
Lead Acid Battery Compliance For Sparta
Northstar | Enersys | Fiamm | Sacred Sun |
NSB (150-210)FT | PowerSafe SBS (100-190)F | 12 FIT 101 | FTA12-100 |
| PowerSafe V-FT (100-190) | 12 FIT 100/23 | FTA12-150 |
|
| 12 FIT 150 | FTA12-200 |
|
| 12 FIT 180 |
|
|
| 12 FIT 201 |
|
|
| 12 FHT 101 |
|
|
| 12c FHT 181 |
|
|
| 12 FHC 95 |
|
|
| 12 FHC 175 |
|
|
| 12 FLB 700 |
|
Installation Video
...