Rectifier type - live metrics effected
...
Rectifier type - alarms effected
...
1.31
...
Vertiv - Solar modules OIDs update
...
Vertiv 830&820
...
1.3
...
Fix of upgrade issue
...
1.29
...
DELTA alarm_PLD was always on (debug) - fixed
...
Delta Orion - relevant only as a fix for 1.28
...
1.28
...
Delta traps – LVD/PLD added
Version upgrade fix (Power center)
ELTEK Solar total power – information restored
...
Eltek - Solar
...
Delta Orion - LVD+PLD only
...
1.27
...
Solar module 1-4 Voltage - DELTA - OIDs change
...
Delta Orion - Solar
...
1.26
...
EXICOM solar current OID
VERTIV M530B – new alarm codes
Solar modules #1 → 4 for the following rectifiers modules:
Delta
Eltek
Vertiv 830&820
...
Exicom - Solar
Vertiv 830&820 - Solar
...
Vertiv 530
...
1.25
...
Vertiv - Total KWH OID added .1.3.6.1.4.1.6302.2.1.2.9.2.0
EXICOM
...
Vertiv 830&820
...
1.24
...
eth_VERTIV_M530B device added
eth_VERTIV_M830D_NCU was [eth_EMERSON_ANY]
eth_VERTIV_M820D_ACU_PLUS added (same as eth_VERTIV_M830D_NCU, which was eth_EMERSON_ANY)
...
Vertiv 530
...
1.23
...
Delta rectifier version 7.6 SNMP support
...
Delta Orion - version 7.6+
...
1.22
...
eSite (ex Flexensclosure) SNMP Rectifier Support
Emerson OID Update:
OID_EMERSON_Load_Total 1.3.6.1.4.1.6302.2.1.2.18.19.0 (NEW)
OID_EMERSON_Solar_Power 1.3.6.1.4.1.6302.2.1.2.17.5.0 3.2020
OID_EMERSON_Solar_Total_Power 1.3.6.1.4.1.6302.2.1.2.18.7.0 3.2020
...
eSite
...
1.21
...
Delta PSC3 support
...
Delta PSC3
...
1.2
...
ELTEK SMARTPACK S rectifier SNMP support
...
Eltek
...
1.19
...
Emerson – solar power OID’s correction
Emerson – updated new alarm codes
ELTEK SNMP support – device added
...
1.18
...
Fix ZTE issue from version 1.17
...
1.17
...
Emerson - Battery current is byte size varient.. it changes according to the value, but still 2s-comlienment
Same was done (as for Emerson battery) for Delta & Huawei
...
1.16
...
Emerson – support negative values
...
1.15
...
ZTE fix from version 1.14
Emerson alarms – fixed and checked for ACU+ and NCU
Delta alarms (snmp) added
case 32851: alarms->alarm_batt_fuse_MC
case 32972: alarms->alarm_temperature_high
case 32770: alarms->alarm_batt_fuse_MC
...
Delta Orion version below 7.6
ZTE for eth versions above 1.04
...
1.14
...
huawei solar data added (to snmp query, and to the generic modbus result mapping)
...
Huawei - Solar
...
1.13
...
Skipped
...
1.12
...
Emerson - under the alarms parsing:
data->field_object.size--; //mask the last OID code.. its a running number
TO:
data->field_object.size--; //mask the last OID code.. its a running number
As per the integration of Huawei, the last .X of the OID, which we are trying to mask is not always one byte...
Huawei alarms implemented (Textual compare)
snmp->protocol.working_community was added (Huawei does not support "public".. only "Public")
...
Huawei
...
1.11
...
Emerson - NCU alarms support. The bulk request payload has been changed - tested on both ACU+ and NCU and its working
eth_HUAWEI_SMU02C added
...
Huawei
...
1.1
...
eth_EMERSON_ACU_PLUS changed to eth_EMERSON_ANY
...
1.09
...
Cutthrough support (RCL)
...
1.08
...
Alarms updates after testing for Delta and Emerson ACU+
...
1.07
...
Skipped
...
1.06
...
Emerson ACU+ device added
...
1.05
...
delta internal temperature was missing factor of 10
...
1.04
...
status byte added to device broadcast
...
1.03
...
first functional version (ZTE support)
...
ZTE
...
1.02
...
Skipped
...
1.01
...
|