Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Version

Power Center parameter name

Parameter

Rectifier

2.01 (Last Version For The Product)

New Supported Parameters

Rectifier_Current

I Rectifier

Delta_Orion 6.5 Outdoor
Delta_Orion 76_79_89
Eltek_SmartPackS
eSite

Temperature Ambient

Ambient Temperature

Delta_Orion 6.5 Outdoor
Delta_Orion 76_79_89
eSite

Solar_5_Voltage
Solar_6_Voltage
Solar_7_Voltage
Solar_8_Voltage

Solar5 Voltage
Solar6 Voltage
Solar7 Voltage
Solar8 Voltage

Delta_Orion 6.5 Outdoor
Delta_Orion 76_79_89
Eltek_SmartPackS
Vertiv_M820B_NCU vertiv_m830b_v3230

Solar_5_Current
Solar_6_Current
Solar_7_Current
Solar_8_Current

Solar5 Current
Solar6 Current
Solar7 Current
Solar8 Current

Delta_Orion 6.5 Outdoor
Delta_Orion 76_79_89
Eltek_SmartPackS
Vertiv_M820B_NCU vertiv_m830b_v3230


DG Signal


DG Start signal

Delta_Orion 6.5 Outdoor
Delta_Orion 76_79_89
Eltek_SmartPackS
eSite

Solar_1_Voltage
Solar_2_Voltage
Solar_3_Voltage

Solar1 Voltage
Solar2 Voltage
Solar3 Voltage


eSite

Grid_Voltage_Phase_1
Grid_Voltage_Phase_2
Grid_Voltage_Phase_3

Grid V Phase 1
Grid V Phase 2
Grid V Phase 3


eSite

Version

Details

Rectifier type -  live metrics effected

Rectifier type - alarms effected

1.31

Vertiv - Solar modules OIDs update

Vertiv 830&820

1.3

Fix of upgrade issue

1.29

DELTA alarm_PLD was always on (debug) - fixed

Delta Orion - relevant only as a fix for 1.28

1.28

Delta traps – LVD/PLD added
Version upgrade fix (Power center)
ELTEK Solar total power – information restored

Eltek - Solar

Delta Orion - LVD+PLD only

1.27

Solar module 1-4 Voltage - DELTA - OIDs change

Delta Orion - Solar

1.26

EXICOM solar current OID
VERTIV M530B – new alarm codes
Solar modules #1 → 4 for the following rectifiers modules:
Delta
Eltek
Vertiv 830&820

Exicom - Solar
Vertiv 830&820 - Solar

Vertiv 530

1.25

Vertiv - Total KWH OID added .1.3.6.1.4.1.6302.2.1.2.9.2.0
EXICOM 

Vertiv 830&820

1.24

eth_VERTIV_M530B device added
eth_VERTIV_M830D_NCU was [eth_EMERSON_ANY]
eth_VERTIV_M820D_ACU_PLUS added (same as eth_VERTIV_M830D_NCU, which was eth_EMERSON_ANY)

Vertiv 530

1.23

Delta rectifier version 7.6 SNMP support

Delta Orion - version 7.6+

1.22

eSite (ex Flexensclosure) SNMP Rectifier Support
Emerson OID Update:
OID_EMERSON_Load_Total                       1.3.6.1.4.1.6302.2.1.2.18.19.0 (NEW)
OID_EMERSON_Solar_Power                    1.3.6.1.4.1.6302.2.1.2.17.5.0          3.2020
OID_EMERSON_Solar_Total_Power        1.3.6.1.4.1.6302.2.1.2.18.7.0          3.2020

eSite

1.21

Delta PSC3 support

Delta PSC3

1.2

ELTEK SMARTPACK S rectifier SNMP support

Eltek

1.19

Emerson – solar power OID’s correction
Emerson – updated new alarm codes
ELTEK SNMP support – device added

1.18

 Fix ZTE issue from version 1.17

1.17

Emerson - Battery current is byte size varient.. it changes according to the value, but still 2s-comlienment
Same was done (as for Emerson battery) for Delta & Huawei

1.16

 Emerson – support negative values

1.15

  1. ZTE fix from version 1.14

  2. Emerson alarms – fixed and checked for ACU+ and NCU

  3. Delta alarms (snmp) added

                case 32851:     alarms->alarm_batt_fuse_MC    
                case 32972:     alarms->alarm_temperature_high
                case 32770:     alarms->alarm_batt_fuse_MC    

Delta Orion version below 7.6
ZTE for eth versions above 1.04

1.14

huawei solar data added (to snmp query, and to the generic modbus result mapping)

Huawei - Solar

1.13

Skipped

1.12

Emerson - under the alarms parsing:
                data->field_object.size--; //mask the last OID code.. its a running number
                TO:
                data->field_object.size--; //mask the last OID code.. its a running number
                As per the integration of Huawei, the last .X of the OID, which we are trying to mask is not always one byte...
Huawei alarms implemented (Textual compare)
snmp->protocol.working_community was added (Huawei does not support "public".. only "Public")

Huawei

1.11

Emerson - NCU alarms support. The bulk request payload has been changed - tested on both ACU+ and NCU and its working
eth_HUAWEI_SMU02C added

Huawei

1.1

eth_EMERSON_ACU_PLUS changed to eth_EMERSON_ANY

1.09

Cutthrough support (RCL)

1.08

Alarms updates after testing for Delta and Emerson ACU+

1.07

Skipped

1.06

Emerson ACU+ device added

1.05

delta internal temperature was missing factor of 10

1.04

status byte added to device broadcast

1.03

first functional version (ZTE support)

ZTE

1.02

Skipped

1.01

first version