The unit will begin transmitting its location every minute (default setting) to allow for tracking and tracing. Once the unit remains 10 minutes (default setting) with no movement, it returns to In-Cabinet Mode.

...

Switching Between Modes

It is possible to switch between the different modes when physically connected to the Sparta (Serial Connection) or when connecting wirelessly (OTA - while the unit is connected to the server).

Important Note - You can switch from "In Cabinet" mode to "Maintenance" mode only when the Sparta is connected to the server. The timing depends on the Sparta's configuration.

Maintenance State Timeout

When Sparta gateway is in one of the following modes: "Storage", "In Cabinet", or "Tracking”, and for some reason, switches to "Maintenance" mode, it will automatically return to the previous mode after one hour, with the exception of the following:

  • Every communication with the host (serial of remote) will reset the 1-hour timer.

  •  If the device is manually set back to maintenance mode (using the power center button), the device will
    remain in maintenance forever.

  • Status is set by the unit itself.

Sparta Status Logic

The Sparta mods and the status in the Galooli solution are linked to facilitate the process of creating an alert.

 Mode

Galooli Solution

Maintenance

Idle

In Cabinet

Off

 

Tracking

On, Stop, Moving

Like all other systems, depends on the speed

Users can generate events in the system and link the mode to the status.

...