Hardware Specification
General specifications
Power Supply | 6 - 16 V |
---|---|
Power Consumption | Storage mode ~25uA |
In Cabinet mode ~25uA | |
Daily report mode (MODEM Only) ~35mA | |
Tracking mode (MODEM+GPS) ~50mA | |
GSM/GPRS | Internal Antenna |
LTE Cat M1/Cat NB1/EGPRS | |
GNSS | Antenna type - Internal |
GNSS Systems 99 acquisition channels Sensitivity -167 dBm | |
Time To First Fix (90% @ -130 dBm) - Cold Start: ‹ 35 s | |
Serial Communication | RS485 |
Memory logger | 10000 messages (Aprox.) |
Storage Temperature | -40 - 85 Celsius |
Working Temperature | -20 - 70 Celsius |
Max. Relative humidity | 90% |
Weight | 34 g (Aprox.) |
Size | 41x86 mm |
Movement detection
Number of Axis | 3 |
---|---|
Full scale | +-2g |
Sampling rate | 50Hz |
Movement detection threshold | 0.25g |
Voltage Measurement
Max voltage | 19v |
---|---|
Resolution | 0.01v |
Accuracy | 0.05v |
Temperature sensor
Sensor type | NTC |
---|---|
Range | [5,50] Celsius |
Resolution | 0.01 Celsius |
Accuracy | 1 Celsius |
Pinout
...
Power
Pin # | Name |
---|---|
1 | V+ |
2 | V+ (not in use) |
3 | V- (not in use) |
4 | V- |
RS485
Pin # | Name |
---|---|
1 | RS485-A |
2 | RS485-B |
3 | GND |
Status LEDs
The LEDs status depends on the type of modem:
...
Status is set by the unit itself.
Sparta Status Logic
The Sparta mods and the status in ZonMax are linked to facilitate the process of creating an alert.
...
Mode
...
ZonMax Status
...
Maintenance
...
Idle
...
In Cabinet
...
Off
...
Tracking
...
On, Stop, Moving
Like all other systems, depends on the speed
Events
Users can generate events in the system and link the mode to the status.
...
It may be necessary to manually configure the Sparta GPS location if there is no cellular GPS reception in a particular location.
Please follow the next steps in order to set the Sparta location manually:
Connect the computer to the Sparta gateway.
Open the Power Center (if the Power Cent was already open, close it, and re-open it).
Open the “Active Device” drop-down menu and select “Power Device”.
Open the “Connect Via” drop-down menu and select the “OTASerial” connection.
...
Provide the relevant login parameters and your Sparta ID.
To set the location manually the Sparta should be in “Maintenance” mode. In order to switch to this mode navigate to the "Sparta" tab and click on “Maintenance Mode”. Please approve the pop-up.
...
Lead Acid Battery Compliance For Sparta
Northstar | Enersys | Fiamm | Sacred Sun |
NSB (150-210)FT | PowerSafe SBS (100-190)F | 12 FIT 101 | FTA12-100 |
| PowerSafe V-FT (100-190) | 12 FIT 100/23 | FTA12-150 |
|
| 12 FIT 150 | FTA12-200 |
|
| 12 FIT 180 |
|
|
| 12 FIT 201 |
|
|
| 12 FHT 101 |
|
|
| 12c FHT 181 |
|
|
| 12 FHC 95 |
|
|
| 12 FHC 175 |
|
|
| 12 FLB 700 |
|
Installation Video
...