Galooli uses the Omnicomm capacitive fuel sensor to read fuel data directly from the fuel tank. Any other fuel sensor utilized by the customer will not be supported by Galooli.
...
Table of Contents |
---|
Preparation
...
Required Tools
Fuel hand pump
RS485 To USB Converter & two 0.5mm thick communication cables. The length of the cables is determined by the distance between the RS485 to the USB converter and the computer
Assorted pair of screwdrivers
¾ inch hollow copper rod.
Measuring tape
Zip-ties
35mm (1.4”) Bi-metal hole saw
Power drill
Fuel (Diesel, Gasoline)
Junction box – we recommend at least IP 65
Configuration Preparation
...
To finish tank calibration, click “Finish the calibration”. To save the calibration table as an XML-file, click “Export”.
IO Configuration
IO Configuration in the Galooli solution is conducted per unit. To configure the IO’s, perform the following steps:
Right-click the selected unit -> Edit Unit -> IOs -> Analog Inputs -> Click to add…
Input: Choose Analog 5
Check ‘V’ in “Main Fuel Tank” checkbox
...
Click on the Magnification Icon to open the calibration table
Calibration with engine computer requires 2 parameters: Liters when the tank is empty and Liters when the tank is full. Enter bother parameters to calibrate the fuel.
...
Click Save to finalize the process.