The accuracy display provide and overview of the validity of the user's settings. The user will be able to choose different X-RAY parameters (e.g., VPMG, float voltage, etc.) and to apply different filters (e.g., battery type, rectifier type, communication node).

Table of Contents

...

X-Ray

...

Dashboard Display

Here, you will find a dashboard with various cards that display the validity of settings as well as a settings history that shows the history of settings over time.

...

Re-click the marked pie section to remove the filter.

...

X-Ray Filtration Tools

There are filter options on the top of the screen that enable the user to focus on sites that have a particular type of device or layout. The user can also change the X-ray items (charts) that appear on the dashboard.

...

Selected Units

Advanced Filter

+Charts

 

 

 

X-Ray Accuracy Report

The purpose of the Accuracy Report is to identify the specific sites with the configuration issues.

In the accuracy report, the data displayed in the dashboard is represented in a table format. As a result, the table's columns include the selected filters and configurations. The table will only display units that are included in the dashboard (and were not filtered out by the filters or pie charts).

After issuance, the report can be filtered and exported to CSV/Excel.

...

Default Settings For Parameters

When the organization does not configure the min, max, and set values via the X-Ray Management tool, the system will use a default values. A calculation is made behind the scenes to compare the actual value with the range specified in the table bellow.

Info

The default values are set just to avoid leaving the display empty for new users. It is strongly recommended to configure your own values.

Name

Min Valid Value

Max Valid Value

Set Value

X-RAY.Rectifier-1-5. DG Off Voltage

56.3

57

56.3

X-RAY.Rectifier-1-5. DG Off Voltage 2

56.3

57

56.3

X-RAY.Rectifier-1-5. DG On Voltage

46.5

50.9

46.5

X-RAY.Rectifier-1-5. Event Controlled Charge Voltage

43.5

57.6

43.5

X-RAY.Rectifier-1-5. Battery Float Voltage

53

57.2

53

X-RAY.Rectifier-1-5.
LVD

42

46.9

42

X-RAY.Rectifier-1-5. Power Up Time

30

320

60

X-RAY.Rectifier-1-5. Temp Compensation Enable

Yes

Yes

Yes

X-RAY.Rectifier-1-5 VPMG Voltage

0.5

1.0

0.8

X-RAY.Rectifier-1-5. Rectifier Float Voltage

53

57.2

57.2

X-RAY.Rectifier-1-5. Solar Float Voltage

53

57.2

57.2