The latest update of the Customer Portal includes features that reflect open dialogue with our customers and Galooli’s desire to facilitate and improve system usage. This article contains information about the main features.
...
Opening Multiple Tabs
In the upcoming version, the side menus of the web solutions and the main selection screen will support the opening link in a new tab/window option. By doing this, you will be able to open several tools in the same organization at once.
New site global fields (Entrance Alarm Sensor)
A new alarm configuration field will be added to the "Global" section in the upcoming version. This alarm is triggered by an "Entrance Alarm Sensor”.
(Configuration>Section: Global>Entrance Alarm Sensor)
New Grid Section Fields
In Two new thresholds have been added to the unit's configurations in the new version, there will be a distinction between . Using the new thresholds, a user can define which voltage is defined as high voltage and as grid unavailability. Furthermore, the user may define the thresholds for availability and high voltage in order to accommodate 220V and 110V gridsavailability, resulting in more customized alarms.
In order to accomplish achieve this distinction, a new section has been created under the "Configuration" submenu (My Units>Configuration>Device Configuration>Section: Grid) that will include several new and other fields:Grid minimal voltage threshold - The minimal voltage level of the grid, so the grid will be defined as “available”. If the value falls below the threshold, an alert will be generated
Grid high voltage threshold - If this threshold is exceeded, the grid might cause damage to electronic and electrical equipment. An alert will be generated if the value exceeds the threshold
Grid Voltage Phase X (1-3) -
Three configuration fields that moved from the “Global” section.
-Grid high voltage threshold -By using the new thresholds, you can determine the values that will impact the alerts of grid availability and high voltage so they can be adapted to both 220 and 110-volt networks.
...
New Generators Fields
In Two new thresholds have been added to the unit's configurations in the new version, two . Using the new thresholds, a user can define which voltage is defined as high voltage and as generator availability, resulting in more customized alarms.The new generator fields have been added to the "Configuration" submenu (My Units>Configuration> Device Configuration>Sectiongenerators section (Live Display>Config>Section: Generators), which will include the following fields:
DG Output minimal voltage threshold - ?The minimal voltage level of the generator, so the generator will be defined as “available”. If the value falls below the threshold, an alert will be generated
DG Output high voltage threshold - ?If this threshold is exceeded, the generator might cause damage to electronic and electrical equipment. An alert will be generated if the value exceeds the threshold
By using the new fields, you can determine the values that will impact the alerts of generator availability and high voltage.
...
New Space Names for Galooli Web Solution
In the next version, Galooli's WEB solution will have updated names for the various spaces.
...