Item Codes/Data

Meter
Accuracy

Ring
Accuracy

Accuracy
Calculation

Calculation
Examples

Galooli Item Code

Voltage reading accuracy

Current reading accuracy

CT Accuracy

Overall voltage accuracy

Overall current accuracy

Overall kwh
accuracy

Input voltage

Voltage-

Voltage+

Input current

Current-

Current+

Kwh

Kwh-

Kwh+

400-ACMetCE42CT-502 (Meter)

0.50%

0.50%

400-AcRin24H30A1A-502 (Ring)

0.50%

0.50%

0.50%

0.50%

1.00%

1.50%

230

227.5

232.5

150

-148.5

+151.5

200

-197

+203

400-AcRin24H50A1A-502 (Ring)

0.50%

0.50%

0.50%

0.50%

1.00%

1.50%

230

227.5

232.5

50

-49.5

+50.5

200

-197

+203

400-AcRin24H150A1A-502 (Ring)

0.50%

0.50%

1.00%

0.50%

1.50%

2.00%

230

227.5

232.5

30

-29.55

+30.45

200

-196

+204

400-AcRin36H30A1A-502 (Ring)

0.50%

0.50%

0.50%

0.50%

1.00%

1.50%

230

227.5

232.5

150

-148.5

+151.5

200

-197

+203

400-AcRin36H50A1A-502 (Ring)

0.50%

0.50%

0.50%

0.50%

1.00%

1.50%

230

227.5

232.5

50

-49.5

+50.5

200

-197

+203

400-AcRin36H150A1A-502 (Ring)

0.50%

0.50%

1.00%

0.50%

1.50%

2.00%

230

227.5

232.5

30

-29.55

+30.45

200

-196

+204

400-ACMetAJ42B-502
(Ring)

0.50%

0.50%

1.00%

230

225

235

200

-199

+201

200

-198

+202

400-AcRin150A5A-502
(Ring)

0.50%

0.50%

1.00%

0.50%

1.50%

2.00%

230

228.8

231.2

150

-147.75

+152.25

200

-196

+204

400-AcRin50A5A-502
(Ring)

0.50%

0.50%

3.00%

0.50%

3.50%

4.00%

230

228.8

231.2

50

-44.75

+55.25

200

-192

+208